Intermittent Fault
WARNING: This page is about a different car, the 2002 Volvo C70, 2001 Volvo C70, 2000 Volvo C70, 1999 Volvo C70, and 1998 Volvo C70. However, it is still accessible from the selected car via links, so may be relevant.
Check signal cable between ECC control module #A29 and damper motor terminal 3 for an intermittent short-circuit to ground according to Short-Circuit To Ground, Intermittent Faults .
Check cable for power supply between ECC control module #A7 and damper motor terminal 2 for an intermittent open-circuit according to Open-Circuit, Intermittent Faults .
Other information:
- To access/replace recirculation damper motor, refer to Replacing Damper Motor Recirculation .
- To connect the breakout box, see Connection Of Breakout Box ECC .
- To remove the control module, refer to Replacing ECC Control Module .
- Voltage on signal cable varies between approximately 0-5 V depending on damper motor position. Damper motor power supply should be approximately 5 V. For other values, see Signal Specification ECC .
- Continue
Refer to Information