Intermittent Fault
Check the ECC control module and engine control module (ECM) connectors for contact resistance and oxidation according to Contact Resistance And Oxidation .
Check cable between ECC control module #B2 and engine control module (ECM) for an intermittent open-circuit according to Open-Circuit, Intermittent Faults and an intermittent short-circuit to supply voltage according to Short-circuit to supply voltage, intermittent faults , and an intermittent short-circuit to ground according to Short-Circuit To Ground, Intermittent Faults .
Also check cable between ECC control module #B2 and combined instrument panel #A26 for an intermittent short-circuit to supply voltage according to Short-Circuit To Supply Voltage, Intermittent Faults and an intermittent short-circuit to ground according to Short-Circuit To Ground, Intermittent Faults .
Remedy as necessary.
Other information:
- To disconnect ECC control module, refer to Replacing ECC control module .
- Connection of breakout box to ECC control module, refer to Connection of breakout box ECC .
- The frequency on the coolant temperature signal varies with the temperature. For other values, see Signal specification ECC .
- Continue
Refer to Information