Intermittent Fault
Check outside temperature sensor and control module connectors for contact resistance and oxidation according to Contact Resistance And Oxidation .
Check cable between ECC control module #A19 and outside temperature sensor terminal 2 for an intermittent open-circuit according to Open-Circuit, Intermittent Faults and an intermittent short-circuit to supply voltage according to Short-Circuit To Supply Voltage, Intermittent Faults .
Check cable between control module #A22 and outside temperature sensor terminal 4 for an open-circuit according to Open-Circuit, Intermittent Faults and an intermittent short-circuit to supply voltage according to Short-Circuit To Supply Voltage, Intermittent Faults .
Remedy as necessary.
Other information:
- To remove the control module, refer to Replacing ECC Control Module .
- To access the outside temperature sensor, see Replacing Outside Temperature Sensor (Electronic Climate Control) .
- To connect the breakout box, see Connection Of Breakout Box ECC .
- The voltage on the signal cable varies with temperature. At 20°C voltage should be approximately 2.5 V. For other values, see Signal Specification ECC .
- Continue
Refer to Information
OKAY: Troubleshooting has been completed.