Climate Units - Specifications, Other
- Description Of Parameters. Climate Control Module CCM (2001-2004)
- Description Of Parameters
- General Information
- Sun Intensity, Value (Electronic Climate Control)
- Evaporator Temperature, Value (Electronic Climate Control, Manual Climate Control)
- Twilight Intensity, Value
- Power Supply, Delayed X-Supply, Value
- Matrix Voltage, Value
- Cabin Temperature (ECC)
- Outside Temperature
- Blower Fan Motor Power Unit, Diagnostic Signal, Value
- Guide Current For the Blower Fan Motor Power Unit, Value
- Lower Switch Approval, Status
- Lower Switch, Status
- Lower Switch Identity, Status
- Temperature Damper Motor, Left Position, Value
- Temperature Damper Motor, Right Position, Value
- Recirculation Damper Motor Position, Value
- Floor/Ventilation Damper Motor Position, Value (Electronic Climate Control)
- Defroster Damper Motor Position, Value (Electronic Climate Control)
- Air Distribution Damper Motor Position, Value (Manual Climate Control/Standard)
- Air Distribution Selector, Defroster Position, Status (Manual Climate Control/Standard)
- Air Distribution Selector, Ventilation Position, Status (Manual Climate Control/Standard)
- Air Distribution Selector, Floor Position, Status (Manual Climate Control/Standard)
- Air Distribution Selector, Floor/Defroster Position, Status (Manual Climate Control/Standard)
- Temperature Damper Motor, Left Activation, Value
- Temperature Damper Motor, Right Activation, Value
- Recirculation Damper Motor Activation, Value
- Floor/Ventilation Damper Motor Activation, Value (Electronic Climate Control)
- Defroster Damper Motor Activation, Value (Electronic Climate Control)
- Air Distribution Damper Motor Activation, Value (Manual Climate Control/Standard)
- Air Quality Sensor, Value (Electronic Climate Control)
- Vehicle Communication Information, Climate Control Module (CCM) (2005-2009)
- Description Of Parameters
- Parameters, Status
- Parameters, Value
- Evaporator Temperature
- Passenger Compartment Temperature Sensor (Only ECC)
- Desired Position, Damper Motor, Defroster
- Actual Position, Damper Motor, Defroster
- Desired Position, Damper Motor, Recirculation
- Actual Position, Damper Motor, Recirculation
- Desired Position, Damper Motor, Temperature Left
- Actual Position, Damper Motor, Temperature Left
- Desired Position, Damper Motor, Temperature Right
- Actual Position, Damper Motor, Temperature Right
- Desired Position, Damper Motor, Air Distribution
- Actual Position, Damper Motor, Air Distribution
- Requested Blower Fan Speed
- Power Supply
- Description Of Reading Off Extended Diagnostic Trouble Code (DTC) Information