LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2002 >> S60 Base, 2.4 61, Standard >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Engine Control Module (ECM) - Diagnostic Trouble Codes And Associated Procedures - 8 Of 14 >> ECM-5000: Air Conditioning (A/C) Pressure Sensor. Signal Too High. Intermittent Fault (B5244S; 2001-2002) >> Signal too high. Intermittent fault >> Checking >> Checking wiring and connectors

Checking wiring and connectors

Check control module and air conditioning (A/C) pressure sensor connector for contact resistance and oxidation according to Contact resistance and oxidation , and loose connections according to Loose connections (terminals) .

Check signal cable between engine control module (ECM) #A21 (#A21) and air conditioning (A/C) pressure sensor terminal 2 for an intermittent short-circuit to ground according to Open-circuit, intermittent faults , and an intermittent short-circuit to supply voltage according to Short-circuit to supply voltage, intermittent faults .

Check cable between control module #A58 (#A58) and air conditioning (A/C) pressure sensor terminal 3 for an intermittent open-circuit according to Open-circuit, intermittent faults .

Other information: 

Fig 1: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.