Checking cables
Check signal cable (+) between control module #A42 and heated oxygen sensor (HO2S) connector terminal 4 for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults .
Check signal cable (-) between control module #A41 and heated oxygen sensor (HO2S) connector terminal 3 for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults .
Other information
- To connect the breakout box, see connecting the breakout box
- To access the control module, see Replacing the engine control module (ECM)
- To access/replace the heated oxygen sensor (HO2S), see Heated oxygen sensor (HO2S), replacing
- For information about signals, see Signal specification
- Continue