Checking components and wiring
HINT: If the cable and the combined instrument panel are fault free the voltage between terminals #1 and #2 on the outside temperature sensor connector must be approximately 5 V.
Check the signal cable between combined instrument panel terminal #A19 (#49) and outside temperature sensor terminal #1. Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- See Checking wiring and terminals. Permanent fault
- To connect the breakout box, see Connecting the breakout box
- To access and replace the combined instrument panel, see Driver information module, removing/installing
- To access or replace the outside temperature sensor, see Replacing the outside temperature sensor
- For information about signals, see Signal specification .
- Continue
Refer to Verification