Checking components and wiring
HINT: If the cable and the combined instrument panel are fault free the voltage between terminals #A and #C on the fuel level sensor connector must be approximately 5 V.
Check the signal cable between fuel level sensor terminal #A and combined instrument panel terminal #B17 (#17). Check for a short-circuit to ground.
Remedy as necessary.
Other information:
- See Checking wiring and terminals. Permanent fault
- To connect the breakout box, see Connecting the breakout box
- To access and replace the combined instrument panel, see Driver information module, removing/installing
- To access or replace the fuel level sensor, see Fuel level sensor, replacing
- For information about signals, see Signal specification .
- Continue
Refer to Verification