Checking components and wiring
HINT: If the cable and the combined instrument panel are fault free the voltage between terminals 1 and 2 on the outside temperature sensor connector should be approximately 5 V.
Check outside temperature sensor connector for Contact resistance and oxidation .
Check the signal cable between the outside temperature gauge terminal 1 and the combined instrument panel terminal A19 (#A19) for a short-circuit to voltage according to Short-circuit to supply voltage. Permanent faults , and an open-circuit according to Open-circuit, permanent faults .
Check the ground lead between the outside temperature gauge terminal 2 and the combined instrument panel terminal A12 (#A12) for a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults , and an open-circuit according to Open-circuit, permanent faults .
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box .
- To access/replace the combined instrument panel, see Driver information module (DIM), installation/removal, component replacement .
- To access/replace the outside temperature sensor, see Replacing the outside temperature sensor .
- For information about signals, see Signal specification .