Home >> Volkswagen >> 2023 >> ID.4 S >> Repair and Diagnosis >> External Pages >> Different car >> Section 130 (Air Conditioning (Refrigerant R1234YF Servicing)) >> 87 Air Conditioning >> Working With A/C Service Station >> Contaminated Refrigerant, Filling In Recycling Cylinder For Analysis, Processing, Or Disposal >> RECYCLING CYLINDER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS 581 011

RECYCLING CYLINDER, FILLING WITH CONTAMINATED REFRIGERANT USING Extraction Unit:VAS 581 011

WARNING: This page is about a different car, the 2023 Volkswagen Arteon. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

Procedure 

Vehicles with High-Voltage System

-- Deactivate the "parking air conditioner". Refer to Owner's Manual.

Vehicles with high-voltage system, for which electric activated valves in the refrigerant circuit are not open when de-energized.

-- Open the electric activated valves for the refrigerant circuit for extracting, evacuating and filling. Refer to Refrigerant Circuit and the Vehicle Diagnostic Tester .

Tip

For vehicles with high-voltage system and secondary functions of the A/C system, valves may be installed in the refrigerant circuit. To guarantee correct draining, evacuating and filling of the refrigerant circuit, no segments are allowed to be closed off. That is why the valves need to be opened before respective work procedures. Refer to Refrigerant Circuit .

Continuation for all vehicles

-- Switch off the ignition.

-- Connect the Extraction Unit:VAS 581 011  according to the included Owner's Manual with the vehicle and the A/C Service Station R1234yf.

-- Fill the contaminated refrigerant using the Extraction Unit:VAS 581 011  in the recycling cylinder. Refer to the Owner's Manual.

-- Fill out the supplement data sheet for the recycling cylinder with contaminated refrigerant and secure on the recycling cylinder.

-- Return the filled recycling cylinder via the supplier, while paying attention to the applicable laws.

-- Evacuate the refrigerant circuit with the A/C Service Station for at least one hour. Refer to REFRIGERANT CIRCUIT, EVACUATING .