Refrigerant Circuit, Evacuating

WARNING: This page is about a different car, the 2023 Volkswagen Arteon. However, it is still accessible from the selected car via links, so may be relevant.

Special tools and workshop equipment required 

CAUTION:

Risk of damaging the A/C compressor by the refrigerant circuit vacuum.

- Never start the engine with vacuum in the refrigerant circuit.

Procedure 

Vehicles with High-Voltage System

-- Deactivate the "parking air conditioner". Refer to Owner's Manual.

Vehicles with high-voltage system, for which electric activated valves in the refrigerant circuit are not open when de-energized.

-- Open the electric activated valves for the refrigerant circuit for extracting, evacuating and filling. Refer to Refrigerant Circuit and the Vehicle Diagnostic Tester .

Tip

For vehicles with high-voltage system and secondary functions of the A/C system, valves may be installed in the refrigerant circuit. To guarantee correct draining, evacuating and filling of the refrigerant circuit, no segments are allowed to be closed off. That is why the valves need to be opened before respective work procedures. Refer to Refrigerant Circuit .

Continuation for all vehicles

-- Switch off the ignition.

-- Start the A/C Service Station according to its operating instructions. Refer to the A/C Service Station Operating Instructions.

-- Connect the A/C Service Station to the refrigerant circuit. Refer to A/C SERVICE STATION ON REFRIGERANT CIRCUIT, CONNECTING .

-- Evacuate the refrigerant circuit and perform a vacuum test. Monitor the following reference values at the A/C Service Station.

The refrigerant circuit was not opened and there are no signs of leaks.

Tip

Depending on the A/C Service Station it may be the case that the time references must not fall short of a specified duration.

The refrigerant circuit was open

Continuation for all vehicles

Possible causes of malfunction for not reaching the vacuum during the evacuation process:

Possible causes of malfunction for not reaching the vacuum during the vacuum/pressure increase test:

Tip

If the vacuum reading does not change (and the pressure remains smaller than 20 mbar) the system does not have leaks and can be filled.