Add UV leak detection additive to the refrigerant circuit using the.
WARNING: This page is about a different car, the 2023 Volkswagen Arteon. However, it is still accessible from the selected car via links, so may be relevant.
- Vacuum test successfully completed. Refer to REFRIGERANT CIRCUIT, EVACUATING .
-- Fill the refrigerant circuit with Leak Detection Additive and refrigerant, following the instructions. Refer to REFRIGERANT CIRCUIT, CHARGING and , Parts Information.
Quantities for UV leak detection additive:
- The quantity of UV leak detection additive is depending on the specified quantity of refrigerant oil required for the refrigerant circuit. Refer to TECHNICAL DATA .
- Refrigerant circuits with a specified capacity of refrigerant oil < 150cm3 : 3.0 ±0.5 ml
- Refrigerant circuits with a higher specified quantity of refrigerant oil. Example 250cm3 : 5.0 ±0.5 ml
- If UV leak detection additive was filled already in a refrigerant circuit for an earlier repair, note the following: only add new UV leak detection additive if the refrigerant oil will be replaced. If only a portion of the refrigerant oil was replaced, only add a proportionate amount of the UV leak detection additive. For example, if 50 ml of refrigerant oil was replaced in a vehicle with 150 ml, then only 1.0 ml (cm3) of UV leak detection additive is allowed to be added.
Tip
- When filling the Leak Detection Additive using a A/C Service Station, the capacity to be set may differ. Refer to Owner's Manual.
-- After filling the Leak Detection Additive, mark the refrigerant circuit using the Sticker:VAS 6201/7 .
-- Clean the service connections and their surroundings from remains of the Leak Detection Additive. For this, use absorbent paper and Cleaning Solution -VAS 6201/3-.