LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2018 >> Beetle S, 2D Hatchback >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 6 (General, Technical Data (Refrigerant R134A General Information) (Convertible)) >> 00 General, Technical Data >> WORKING WITH A/C Service Station >> A/C Service Station, CONNECTING FOR MEASURING AND TESTING

A/C Service Station, CONNECTING FOR MEASURING AND TESTING

WARNING: This page is about a different variant/trim than selected.
NOTE:

The work procedure is always to be performed as described in the operating instructions for the A/C Service Station.

The charging hoses are to be connected as follows to prevent the ingress of air or moisture into the refrigerant circuit:

-- Switch off the ignition.

-- Connect the A/C Service Station to the power supply.

-- Remove the cap from the service connections or connections with a valve (see vehicle-specific refrigerant circuit).

Refer to COMPONENT LOCATION OVERVIEW - COMPONENTS OUTSIDE OF VEHICLE INTERIOR .

-- Evacuate the filler hose.

NOTE:

Connect filler hose with quick-release couplings to refrigerant circuit service connections.

CAUTION:

Risk of damaging the A/C compressor or the A/C service station.

A short circuit between the high and low pressure side is possible when opening the valves with the A/C system is on.

- Never open the valves in the high or low pressure side when the A/C system is on.

-- Only tighten the hand wheel in the quick-release coupling just enough so the service connection is open. Watch the pressure gauge and do not place too much pressure on the valve.

-- Start the engine and perform the planned tests and measurements.

-- Compare values determined to specified measured values. Refer to REFRIGERANT CIRCUIT PRESSURES, CHECKING (WITH A/C Service Station) .

-- Loosen the hand wheel to close the quick-release coupling before disconnecting it.