LEMON Manuals: Even more car manuals for everyone
Home >> Volkswagen >> 2018 >> Beetle S, 2D Hatchback >> Repair and Diagnosis >> External Pages >> Different car >> Section 132 (Refrigerant R134A Servicing (Hatchback)) >> 00 General, Technical Data >> Refrigerant Circuit, Removing Contaminants >> Refrigerant Circuit, Flushing With Compressed Air And Nitrogen >> General Information

General Information

WARNING: This page is about a different car, the 2016 Volkswagen Beetle, 2015 Volkswagen Beetle, 2014 Volkswagen Beetle, 2013 Volkswagen Beetle, and 2012 Volkswagen Beetle. However, it is still accessible from the selected car via links, so may be relevant.

Only individual components should be flushed if:

NOTE:

Blowing compressed air and nitrogen through the refrigerant circuit does not achieve the level of cleanliness as flushing with refrigerant R134a. Flushing with refrigerant R134a loosens the refrigerant oil and the components are then cleaner, refer to REFRIGERANT CIRCUIT, FLUSHING (CLEANING) WITH REFRIGERANT R134A .

When blowing, working pressure must not exceed a maximum of 15 bar, (also use a pressure reducer for compressed air if necessary).

WARNING:
  • Nitrogen can leak uncontrolled from the cylinder.
  • Make exclusive use of pressure reducers for nitrogen cylinders (maximum work pressure 15 bar).
  • Use appropriate emissions extraction units to draw off gas mixture escaping from components.

-- Always flush components in direction opposite of refrigerant flow direction.

Restrictor, expansion valve, compressor, receiver and reservoir cannot be flushed with compressed air and nitrogen.

-- Remove this dryer cartridge on condensers that have one installed in the integrated receiver/dryer.

-- First blow out dirt with compressed air, then remove moisture from components with nitrogen.

-- Connect adapter to connect the pressure hose to the refrigerant circuit, refer to ADAPTER FOR ASSEMBLING FLUSHING CIRCUIT  and Heating & Air Conditioning.

Note the following points to prevent oil and moisture from entering the refrigerant circuit from the compressed air system.

NOTE:

Compressed air/nitrogen emerging from components is to be drawn off by way of an appropriate system (e.g. workshop extraction system).

Certain contaminants cannot be removed or can only be removed insufficiently from the refrigerant circuit with compressed air. These contaminants can only be removed by flushing with refrigerant R134a, refer to REFRIGERANT CIRCUIT, FLUSHING (CLEANING) WITH REFRIGERANT R134A .