Reducing Agent Delivery Module, Removing And Installing: Removing
-- Drain the reducing agent tank. Refer to REDUCING AGENT TANK, DRAINING .
-- Remove the reducing agent tank. Refer to REDUCING AGENT TANK, REMOVING AND INSTALLING .
-- Remove the filler tube OVERVIEW - REDUCING AGENT TANK - Filler Neck.
-- Place the reducing agent tank on a clean surface with the delivery module facing upward.
-- Clean the area around the delivery module.
-- Disconnect the connectors -1 and 3-.
-- Release and disconnect the reducing agent line -2-. Disconnect the reducing agent line. Refer to Disconnecting the Connector for the Reducing Agent .
-- To catch escaping reducing agent place a clean cloth under the separation point.
-- Seal all the open lines and connections with clean plugs from the :VAS6122 .
-- Remove the bolts -arrows-.
-- Pry out the delivery module -5- from the opening -4- with a slotted screwdriver.
-- Remove the delivery module from the reducing agent tank.