Coolant Thermostat
Special tools and workshop equipment required
- T Bar and Socket 10 mm 3185
- Refractometer T10007
- Hex Ball Socket T10058
- Torque Wrench (5-50 Nm) V.A.G 1331
- Drip Tray for VAS 6100 VAS 6208
- Hose Clip Pliers 6362
Removing
-- Drain the coolant. Refer to DRAINING AND FILLING .
-- Remove the throttle valve control module -J338-. Refer to INTAKE MANIFOLD AND ATTACHMENTS OVERVIEW .
-- Remove the coolant hose from the connecting piece.
-- Loosen the bolts -4- for the connecting piece -3- using the T bar and socket 10 mm 3185, and remove using the hex ball socket T10058. Remove the connecting piece -3- with the coolant thermostat -1-.
-- Rotate the coolant thermostat -1- 90° (1/4) to the left and remove it from the connecting piece -3-.
Installing
Install in reverse order of removal. When doing this note the following:
- Always replace seals, sealing rings and O-rings.
-- Lubricate the new O-ring -2- with coolant.
-- Insert the coolant thermostat -1- into the connecting piece -3- and turn it 90° (1/4) turn to the right.
The clip of the thermostat must be positioned at approximately a right angle.
-- Position the connecting piece -3- with the coolant thermostat -1- to the cylinder block.
-- Tighten the bolts -4- using the T bar and socket 10 mm 3185.
- Tightening specification: 15 Nm.
-- Install the coolant hose to the connecting piece.
-- Install the throttle valve control module. Refer to INTAKE MANIFOLD AND ATTACHMENTS OVERVIEW .
-- Fill with coolant. Refer to DRAINING AND FILLING .