Air Ionizer Removal And Installation/Replacement
Mobile Repair Possible: No
Removal Procedure:
- Remove HVAC assembly. Refer to HVAC ASSEMBLY REMOVAL AND INSTALLATION/REPLACEMENT
- Unlock and disconnect electrical connector (1).
- Remove 2 screws (2)
Torque: 1 Nm
- Remove air ionizer (3).
Installation Procedure:
- Installation is the reverse of removal procedure, noting the following. All fasteners must be tightened to torque specification!
- Install HVAC assembly. Refer to HVAC ASSEMBLY REMOVAL AND INSTALLATION/REPLACEMENT