Installation [03/2017 - ]: Procedure
- INSTALL WATER INLET WITH THERMOSTAT SUB-ASSEMBLY
- Install a new gasket to the water inlet with thermostat sub-assembly.
HINT:
Be sure to clean the contact surfaces.
- Using an 8 mm socket wrench, install the water inlet with thermostat sub-assembly with the 2 bolts.
Torque: 10 N*m (102 kgf*cm, 7 ft.*lbf)
- Connect the No. 7 water by-pass hose to the water inlet with thermostat sub-assembly and slide the clip to secure it.
- Connect the water inlet with thermostat sub-assembly connector.
- Install a new gasket to the water inlet with thermostat sub-assembly.
- CONNECT NO. 2 RADIATOR HOSE
Refer to PROCEDURE - Step 33 [03/2017 - 06/2017] , or refer to PROCEDURE - Step 33 [06/2017 - 08/2018] , or refer to PROCEDURE - Step 33 [08/2018 - 03/2020] , or refer to PROCEDURE - Step 37 [03/2020 - 10/2020] , or refer to PROCEDURE - Step 37 [10/2020 - ]
- INSTALL GENERATOR ASSEMBLY
Refer to INSTALLATION [03/2017 - ]
- ADD ENGINE COOLANT
Refer to PROCEDURE - Step 2 [03/2017 - 06/2017] , or refer to PROCEDURE - Step 2 [06/2017 - 08/2018] , or refer to PROCEDURE - Step 2 [08/2018 - ]
- INSPECT FOR COOLANT LEAK
Refer to PROCEDURE - Step 1 [03/2017 - 06/2017] , or refer to PROCEDURE - Step 1 [06/2017 - 08/2018] , or refer to PROCEDURE - Step 1 [08/2018 - ]