LEMON Manuals: Even more car manuals for everyone
Home >> Toyota >> 2020 >> Avalon Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 85 (Blind Spot Monitor System - Diagnostic Codes & Symptom Tests (Hybrid)) >> BLIND SPOT MONITOR SYSTEM (for HV Model) >> Circuit Tests >> Power Source Circuit [04/2018 -] >> Procedure

Power Source Circuit [04/2018 -]: Procedure

WARNING: This page is about a different variant/trim than selected.
  1. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH POWER SOURCE) 
    1. Disconnect the P5 blind spot monitor sensor RH connector.
    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      P5-5 (BRB) - Body ground Power switch on (IG) 11 to 14 V
      P5-5 (BRB) - Body ground Power switch off Below 1 V

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  2

  2. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND) 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      P5-10 (BRGD) - Body ground Always Below 1 Ω

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  3

  3. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH POWER SOURCE) 
    1. Disconnect the P6 blind spot monitor sensor LH connector.
    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage

      Tester Connection Condition Specified Condition
      P6-5 (BLB) - Body ground Power switch on (IG) 11 to 14 V
      P6-5 (BLB) - Body ground Power switch off Below 1 V

      Result

      Proceed to
      OK
      NG

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR 

    Result: 

    OK 

    See step  4

  4. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND) 
    1. Measure the resistance according to the value(s) in the table below.

      Standard Resistance

      Tester Connection Condition Specified Condition
      P6-10 (BLGD) - Body ground Always Below 1 Ω

      Result

      Proceed to
      OK
      NG

    Result: 

    OK 

    PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE. Refer to  PROBLEM SYMPTOMS TABLE [04/2018 -] 

    Result: 

    NG 

    REPAIR OR REPLACE HARNESS OR CONNECTOR