Air Intake Control Circuit [12/2015 - 08/2016]: Procedure
WARNING: This page is about a different car, the 2016 Toyota Sienna. However, it is still accessible from the selected car via links, so may be relevant.
- PERFORM ACTIVE TEST USING TECHSTREAM (ACTIVATE THE VSV FOR AICS)
- Connect the Techstream to the DLC3.
- Turn the ignition switch to ON.
- Turn the Techstream on.
- Enter the following menus: Powertrain / Engine / Active Test / Activate the VSV for AICS.
- Check the operation of the vacuum switching valve (for AICS) when the vacuum switching valve (for AICS) is operated using the Techstream.TEXT IN ILLUSTRATION
*1 Port F *2 Port E *a Vacuum Switching Valve (for AICS) is ON *b Vacuum Switching Valve (for AICS) is OFF *c Air OK
Techstream Operation Specified Condition ON Air from port E flows out through port F OFF Air from port E flows out through the air filter
Result:
OK
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE
(Refer to PROBLEM SYMPTOMS TABLE [12/2015 - 08/2016] )
Result:
NG
See step 2
- CHECK VACUUM SWITCHING VALVE (FOR AICS)
- Check the vacuum switching valve (for AICS) (Refer to ON-VEHICLE INSPECTION [12/2015 - 08/2016] ).
Result:
NG
REPLACE VACUUM SWITCHING VALVE (FOR AICS)
Result:
OK
See step 3
- CHECK TERMINAL VOLTAGE (VACUUM SWITCHING VALVE (FOR AICS))
- Disconnect the vacuum switching valve (for AICS) connector.
- Turn the ignition switch to ON.
- Measure the voltage according to the value(s) in the table below.
Standard Voltage
Tester Connection Switch Condition Specified Condition A31-1 - Body ground Ignition switch ON 11 to 14 V TEXT IN ILLUSTRATION*a Front view of wire harness connector
(to Vacuum Switching Valve (for AICS))
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI NO. 2 FUSE - VACUUM SWITCHING VALVE (FOR AICS))
Result:
OK
See step 4
- Disconnect the vacuum switching valve (for AICS) connector.
- CHECK HARNESS AND CONNECTOR (VACUUM SWITCHING VALVE (FOR AICS) - ECM)
- Disconnect the vacuum switching valve (for AICS) connector.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance (Check for Open)
Tester Connection Condition Specified Condition A31-2 - B1-61 (AICV) Always Below 1 Ω Standard Resistance (Check for Short)
Tester Connection Condition Specified Condition A31-2 or B1-61 (AICV) - Body ground Always 10 kΩ or higher
Result:
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result:
OK
See step 5
- INSPECT AIR CLEANER CAP SUB-ASSEMBLY (VACUUM SURGE TANK)
- Inspect the vacuum surge tank (Refer to PROCEDURE - Step 1 ).
Result:
OK
REPLACE ECM
(Refer to REMOVAL [12/2015 - 08/2016] )
Result:
NG
REPAIR OR REPLACE AIR CLEANER CAP SUB-ASSEMBLY