DTC P0A79-712: Drive Motor "B" Inverter Performance [02/2014 - 11/2016]: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result
Result Proceed to P0A79-712 is set before any of the DTCs in the table below are set. A Any of the DTCs including pending DTCs in the table below are set before P0A79-712 is set. B Relevant DTC P0A9C-123 Hybrid Battery Temperature Sensor "A" Range / Performance P0A9D-123 Hybrid Battery Temperature Sensor "A" Circuit Low P0A9E-123 Hybrid Battery Temperature Sensor "A" Circuit High P0AC0-123 Hybrid Battery Pack Current Sensor Circuit Range / Performance P0AC1-123 Hybrid Battery Pack Current Sensor Circuit Low P0AC2-123 Hybrid Battery Pack Current Sensor Circuit High P0AC6-123 Hybrid Battery Temperature Sensor "B" Range / Performance P0AC7-123 Hybrid Battery Temperature Sensor "B" Circuit Low P0AC8-123 Hybrid Battery Temperature Sensor "B" Circuit High P0ACB-123 Hybrid Battery Temperature Sensor "C" Range / Performance P0ACC-123 Hybrid Battery Temperature Sensor "C" Circuit Low P0ACD-123 Hybrid Battery Temperature Sensor "C" Circuit High P0AE9-123 Hybrid Battery Temperature Sensor "D" Range / Performance P0AEA-123 Hybrid Battery Temperature Sensor "D" Circuit Low P0AEB-123 Hybrid Battery Temperature Sensor "D" Circuit High P0AFC-123 Hybrid Battery Pack Sensor Module P0BC3-123 Hybrid Battery Temperature Sensor "E" Range / Performance P0BC4-123 Hybrid Battery Temperature Sensor "E" Circuit Low P0BC5-123 Hybrid Battery Temperature Sensor "E" Circuit High P0C34-123 Hybrid Battery Temperature Sensor "F" Range / Performance P0C35-123 Hybrid Battery Temperature Sensor "F" Circuit Low P0C36-123 Hybrid Battery Temperature Sensor "F" Circuit High P0C6E-123 Hybrid Battery Temperature Sensor "A" /"B" Correlation P0C70-123 Hybrid Battery Temperature Sensor "C" /"D" Correlation P0C72-123 Hybrid Battery Temperature Sensor "E" /"F" Correlation P3011-123, P3012-123, P3013-123, P3014-123, P3015-123, P3016-123, P3017-123, P3018-123, P3019-123, P3020-123, P3021-123, P3022-123, P3023-123, P3024-123, P3025-123 Battery Block # Becomes Weak P308A-123 Hybrid Battery Voltage Sensor All Circuits Low HINT:
P0A79-712 may be stored due to a malfunction which also causes DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
- Turn the power switch off.
Result: 2
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [02/2014 - 11/2015] Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2015 - 11/2016]
Result: 1
A
See step 2
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result
Proceed to P0A79-716 is not output. P0A79-716 is also output. NOTE:- If P0A79-716 is output, troubleshoot it first. After completing the troubleshooting for P0A79-716, perform troubleshooting for this DTC.
- Parts repaired or replaced during troubleshooting for P0A79-716 do not need to be re-inspected in this diagnostic procedure.
- Turn the power switch off.
Result: 2
P0A79-716 is also output.
GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [02/2014 - 11/2015] Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2015 - 11/2016]
Result: 1
P0A79-716 is not output.
See step 3
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
HINT:
- If P0A79-716 was not output in step 2 of this diagnostic procedure, check Table 1 below.
- If P0A79-716 was output in step 2 of this diagnostic procedure, diagnose that DTC first, then check Table 2 below.
Result
Result Proceed to P0A79-712 only is output, or DTCs except the ones in the tables below are also output. A Any of the following DTCs including pending DTCs are also output. B TABLE 1Relevant DTC P0A1A (all INF codes)*1 Generator Control Module P0A1B (all INF codes)*1 Drive Motor "A" Control Module P0A1C (all INF codes)*1 Drive Motor "B" Control Module P0A1D (all INF codes)*1 Hybrid Powertrain Control Module P0A3F-243 Drive Motor "A" Position Sensor Circuit P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance P0A41-245 Drive Motor "A" Position Sensor Circuit Low P0A45-669 Drive Motor "B" Position Sensor Circuit P0A46-671 Drive Motor "B" Position Sensor Circuit Range / Performance P0A47-670 Drive Motor "B" Position Sensor Circuit Low P0A4B-253 Generator Position Sensor Circuit P0A4C-513 Generator Position Sensor Circuit Range / Performance P0A4D-255 Generator Position Sensor Circuit Low P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current P0A69 (all INF codes)*1 Drive Motor "B" Phase V Current P0A6C (all INF codes)*1 Drive Motor "B" Phase W Current P0A72 (all INF codes)*1 Generator Phase V Current P0A75 (all INF codes)*1 Generator Phase W Current P0A78-118, 119, 120, 266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance P0A79-693, 694, 695, 704, 812, 813, 814 Drive Motor "B" Inverter Performance P0A7A-324, 325, 344, 517, 518, 809, 810, 811 Generator Inverter Performance P0A90-509 Drive Motor "A" Performance P0A91-702 Drive Motor "B" Performance P0A92-521 Hybrid Generator Performance P0A94-124, 125, 126, 169, 170, 171, 442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC / DC Converter Performance P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High P0C76-523 Hybrid Battery System Discharge Time Too Long P3004-803 High Voltage Power Resource TABLE 2Relevant DTC P0A1A (all INF codes)*1 Generator Control Module P0A1B (all INF codes)*1 Drive Motor "A" Control Module P0A1C (all INF codes)*1 Drive Motor "B" Control Module P0A1D (all INF codes)*1 Hybrid Powertrain Control Module P0A3F-243 Drive Motor "A" Position Sensor Circuit P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance P0A41-245 Drive Motor "A" Position Sensor Circuit Low P0A45-669 Drive Motor "B" Position Sensor Circuit P0A46-671 Drive Motor "B" Position Sensor Circuit Range / Performance P0A47-670 Drive Motor "B" Position Sensor Circuit Low P0A4B-253 Generator Position Sensor Circuit P0A4C-513 Generator Position Sensor Circuit Range / Performance P0A4D-255 Generator Position Sensor Circuit Low P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current P0A69-677 Drive Motor "B" Phase V Current P0A6C-678 Drive Motor "B" Phase W Current P0A72 (all INF codes)*1 Generator Phase V Current P0A75 (all INF codes)*1 Generator Phase W Current P0A78-118, 119, 120, 266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance P0A79-693, 694, 695, 812, 813, 814 Drive Motor "B" Inverter Performance P0A7A-324, 325, 344, 517, 518, 809, 810, 811 Generator Inverter Performance P0A90-509 Drive Motor "A" Performance P0A92-521 Hybrid Generator Performance P0A94-124, 125, 126, 169, 170, 171, 442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC / DC Converter Performance P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High P0C76-523 Hybrid Battery System Discharge Time Too Long P3004-803 High Voltage Power Resource HINT:
- *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
- P0A79-712 may be stored due to a malfunction which also causes DTCs in the preceding tables to be stored. In this case, first troubleshoot the output DTCs in the preceding tables. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
- Turn the power switch off.
Result: 2
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [02/2014 - 11/2015] Refer to DIAGNOSTIC TROUBLE CODE CHART [11/2015 - 11/2016]
Result: 1
A
See step 4
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 3
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
A
See step 5
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - REAR MOTOR RESOLVER)
Refer to PROCEDURE - Step 7
Result
Proceed to OK NG Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 6
- CHECK REAR MOTOR RESOLVER
Refer to PROCEDURE - Step 8
Result
Proceed to OK NG Result: 2
NG
See step 20
Result: 1
OK
See step 7
- CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 6 FLOOR WIRE (REAR MOTOR CABLE) CONNECTION CONDITION)
Refer to PROCEDURE - Step 12 Refer to PROCEDURE - Step 12
Result
Result Proceed to The terminals are connected securely and there are no contact problems. There are no arc marks. A The terminals are not connected securely and there is a contact problem. There are arc marks. B The terminals are not connected securely and there is a contact problem. There are no arc marks. C The terminals are connected securely and there are no contact problems. There are arc marks. B Result: 2
B
REPLACE MALFUNCTIONING PARTS
Result: 3
C
CONNECT SECURELY
Result: 1
A
See step 8
- CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (MGR)
Refer to PROCEDURE - Step 15 Refer to PROCEDURE - Step 15
Result
Proceed to OK NG Result: 2
NG
See step 17
Result: 1
OK
See step 9
- CHECK FUSE (PCU)
Refer to PROCEDURE - Step 13 Refer to PROCEDURE - Step 13
Result
Proceed to OK NG Result: 2
NG
See step 14
Result: 1
OK
See step 10
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)
Refer to PROCEDURE - Step 14 Refer to PROCEDURE - Step 14
Result
Proceed to OK NG Result: 2
NG
REPAIR OR REPLACE POWER SOURCE CIRCUIT
Result: 1
OK
See step 11
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
Refer to PROCEDURE - Step 15 Refer to PROCEDURE - Step 15
Result
Proceed to OK NG Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 12
- CHECK POWER MANAGEMENT CONTROL ECU
Refer to PROCEDURE - Step 16 Refer to PROCEDURE - Step 16
Result
Proceed to OK NG Result: 2
NG
REPLACE POWER MANAGEMENT CONTROL ECU. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 1
OK
See step 13
- CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR)
Refer to PROCEDURE - Step 11
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 1
A
REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE)
Refer to PROCEDURE - Step 19 Refer to PROCEDURE - Step 19
Result
Proceed to OK NG Result: 2
NG
See step 16
Result: 1
OK
See step 15
- REPLACE INVERTER WITH CONVERTER ASSEMBLY
Refer to COMPONENTS [02/2014 - 11/2016]
Result
Proceed to NEXT Result: 1
NEXT
REPLACE FUSE (PCU)
- REPAIR OR REPLACE HARNESS OR CONNECTOR
Result
Proceed to NEXT Result: 1
NEXT
REPLACE FUSE (PCU)
- CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (NO. 6 FLOOR WIRE (REAR MOTOR CABLE) CONNECTION CONDITION)
Refer to PROCEDURE - Step 33 Refer to PROCEDURE - Step 33
Result
Result Proceed to The terminals are connected securely and there are no contact problems. There are no arc marks. A The terminals are not connected securely and there is a contact problem. There are arc marks. B The terminals are not connected securely and there is a contact problem. There are no arc marks. C The terminals are connected securely and there are no contact problems. There are arc marks. B Result: 2
B
REPLACE MALFUNCTIONING PARTS
Result: 3
C
CONNECT SECURELY
Result: 1
A
See step 18
- CHECK NO. 6 FLOOR WIRE (REAR MOTOR CABLE)
Refer to PROCEDURE - Step 34 Refer to PROCEDURE - Step 34
Result
Proceed to OK NG Result: 2
NG
REPLACE NO. 6 FLOOR WIRE. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 1
OK
See step 19
- CHECK EXTENSION WIRE ASSEMBLY
Refer to PROCEDURE - Step 35 Refer to PROCEDURE - Step 35
Result
Proceed to OK NG Result: 1
OK
REPLACE REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 2
NG
REPLACE EXTENSION WIRE ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2016]
- CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR)
Refer to PROCEDURE - Step 12
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
A
See step 21
- INSPECT REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (REAR MOTOR RESOLVER)
Refer to PROCEDURE - Step 13
Result
Proceed to OK NG Result: 1
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 2
NG
REPLACE REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2016]