DTC P0A78-121: Drive Motor "A" Inverter Performance [02/2014 - 11/2015]: Procedure
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result
Result Proceed to P0A78-121 is stored before any of the DTCs in the table below are stored. A Any of the DTCs including pending DTCs in the table 1 below are stored before P0A78-121 is stored. B Any of the DTCs including pending DTCs in the table 2 below are stored before P0A78-121 is stored. C TABLE 1Relevant DTC P3000-388 Battery Control System P3000-389 Battery Control System P3000-603 Battery Control System P3004-133 High Voltage Power Resource TABLE 2Relevant DTC P0A95-123 High Voltage Fuse P0A9C-123 Hybrid Battery Temperature Sensor "A" Range / Performance P0A9D-123 Hybrid Battery Temperature Sensor "A" Circuit Low P0A9E-123 Hybrid Battery Temperature Sensor "A" Circuit High P0AC0-123 Hybrid Battery Pack Current Sensor Circuit Range / Performance P0AC1-123 Hybrid Battery Pack Current Sensor Circuit Low P0AC2-123 Hybrid Battery Pack Current Sensor Circuit High P0AC6-123 Hybrid Battery Temperature Sensor "B" Range / Performance P0AC7-123 Hybrid Battery Temperature Sensor "B" Circuit Low P0AC8-123 Hybrid Battery Temperature Sensor "B" Circuit High P0ACB-123 Hybrid Battery Temperature Sensor "C" Range / Performance P0ACC-123 Hybrid Battery Temperature Sensor "C" Circuit Low P0ACD-123 Hybrid Battery Temperature Sensor "C" Circuit High P0AE9-123 Hybrid Battery Temperature Sensor "D" Range/Performance P0AEA-123 Hybrid Battery Temperature Sensor "D" Circuit Low P0AEB-123 Hybrid Battery Temperature Sensor "D" Circuit High P0AFC-123 Hybrid Battery Pack Sensor Module P0BC3-123 Hybrid Battery Temperature Sensor "E" Range/Performance P0BC4-123 Hybrid Battery Temperature Sensor "E" Circuit Low P0BC5-123 Hybrid Battery Temperature Sensor "E" Circuit High P0C34-123 Hybrid Battery Temperature Sensor "F" Range/Performance P0C35-123 Hybrid Battery Temperature Sensor "F" Circuit Low P0C36-123 Hybrid Battery Temperature Sensor "F" Circuit High P0C6E-123 Hybrid Battery Temperature Sensor "A" / "B" Correlation P0C70-123 Hybrid Battery Temperature Sensor "C" / "D" Correlation P0C72-123 Hybrid Battery Temperature Sensor "E" / "F" Correlation P3011-123, P3012-123, P3013-123, P3014-123, P3015-123, P3016-123, P3017-123, P3018-123, P3019-123, P3020-123, P3021-123, P3022-123, P3023-123, P3024-123, P3025-123 Battery Block # Becomes Weak P308A-123 Hybrid Battery Voltage Sensor All Circuits Low HINT:
- Refer to the freeze frame data to determine the order in which the DTCs were stored.
- P0A78-121 may be stored due to a malfunction which also causes DTCs in the preceding tables to be stored. In this case, first troubleshoot the output DTCs in the preceding tables. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
- Turn the power switch off.
Result: 3
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [02/2014 - 11/2015]
Result: 2
C
GO TO DTC CHART (HYBRID BATTERY SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [02/2014 - 11/2016]
Result: 1
A
See step 2
- CHECK DTC OUTPUT (HYBRID CONTROL)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
- Check for DTCs.
Powertrain > Hybrid Control > Trouble Codes
Result
Result Proceed to P0A78-121 only is output, or DTCs except the ones in the table below are also output. A Any of the following DTCs including pending DTCs are also output. B Relevant DTC P0A1A (all INF codes)*1 Generator Control Module P0A1B (all INF codes)*1 Drive Motor "A" Control Module P0A1C (all INF codes)*1 Drive Motor "B" Control Module P0A1D (all INF codes)*1 Hybrid Powertrain Control Module P0A3F-243 Drive Motor "A" Position Sensor Circuit P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance P0A41-245 Drive Motor "A" Position Sensor Circuit Low P0A45-669 Drive Motor "B" Position Sensor Circuit P0A46-671 Drive Motor "B" Position Sensor Circuit Range/Performance P0A47-670 Drive Motor "B" Position Sensor Circuit Low P0A4B-253 Generator Position Sensor Circuit P0A4C-513 Generator Position Sensor Circuit Range / Performance P0A4D-255 Generator Position Sensor Circuit Low P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current P0A69 (all INF codes)*1 Drive Motor "B" Phase V Current P0A6C (all INF codes)*1 Drive Motor "B" Phase W Current P0A72 (all INF codes)*1 Generator Phase V Current P0A75 (all INF codes)*1 Generator Phase W Current P0A78-113, 118, 119, 120, 128, 266, 267, 279, 284, 286, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance P0A79-136, 692, 693, 694, 695, 696, 704, 712, 812, 813, 814 Drive Motor "B" Inverter Performance P0A7A-122, 130, 322, 324, 325, 344, 517, 518, 809, 810, 811 Generator Inverter Performance P0A90-509 Drive Motor "A" Performance P0A91-702 Drive Motor "B" Performance P0A92-521 Hybrid Generator Performance P0A93-346 Inverter Cooling System Performance P0A94-124, 125, 126, 169, 170, 171, 172, 442, 547, 548, 549, 553, 554, 555, 556, 557, 585, 587, 589, 590 DC / DC Converter Performance P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High P0C73-776 Motor Electronics Coolant Pump "A" Control Performance P0C76-523 Hybrid Battery System Discharge Time Too Long P3004-803 High Voltage Power Resource P314A-828 Inverter Coolant Pump Speed Signal HINT:
- *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
- P0A78-121 may be stored due to a malfunction which also causes DTCs in the preceding table to be stored. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.
- Turn the power switch off.
Result: 2
B
GO TO DTC CHART (HYBRID CONTROL SYSTEM). Refer to DIAGNOSTIC TROUBLE CODE CHART [02/2014 - 11/2015]
Result: 1
A
See step 3
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
Refer to PROCEDURE - Step 3
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
A
See step 4
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)
Refer to PROCEDURE - Step 3
Result
Proceed to OK NG Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 5
- CHECK GENERATOR RESOLVER
Refer to PROCEDURE - Step 4
Result
Proceed to OK NG Result: 2
NG
See step 40
Result: 1
OK
See step 6
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)
Refer to PROCEDURE - Step 5
Result
Proceed to OK NG Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 7
- CHECK MOTOR RESOLVER
Refer to PROCEDURE - Step 6
Result
Proceed to OK NG Result: 2
NG
See step 38
Result: 1
OK
See step 8
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - REAR MOTOR RESOLVER)
Refer to PROCEDURE - Step 7
Result
Proceed to OK NG Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 9
- CHECK REAR MOTOR RESOLVER
Refer to PROCEDURE - Step 8
Result
Proceed to OK NG Result: 2
NG
See step 36
Result: 1
OK
See step 10
- CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)
Refer to PROCEDURE - Step 9
Result
Result Proceed to The terminals are connected securely and there are no contact problems. There are no arc marks. A The terminals are not connected securely and there is a contact problem. There are arc marks. B The terminals are not connected securely and there is a contact problem. There are no arc marks. C The terminals are connected securely and there are no contact problems. There are arc marks. B Result: 2
B
REPLACE MALFUNCTIONING PARTS
Result: 3
C
CONNECT SECURELY
Result: 1
A
See step 11
- CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
Refer to PROCEDURE - Step 10
Result
Result Proceed to The terminals are connected securely and there are no contact problems. There are no arc marks. A The terminals are not connected securely and there is a contact problem. There are arc marks. B The terminals are not connected securely and there is a contact problem. There are no arc marks. C The terminals are connected securely and there are no contact problems. There are arc marks. B Result: 2
B
REPLACE MALFUNCTIONING PARTS
Result: 3
C
CONNECT SECURELY
Result: 1
A
See step 12
- CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 6 FLOOR WIRE (REAR MOTOR CABLE) CONNECTION CONDITION) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the inverter terminal cover from the inverter with converter assembly.
- Check that the bolts for the No. 6 floor wire (rear motor cable) are tightened to the specified torque, the No. 6 floor wire (rear motor cable) is connected securely, and there are no contact problems.
Specified Condition
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
NOTE:Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
- Disconnect the No. 6 floor wire (rear motor cable) from the inverter with converter assembly.
- Check for arc marks at the terminals for the generator cable.
Result
Result Proceed to The terminals are connected securely and there are no contact problems. There are no arc marks. A The terminals are not connected securely and there is a contact problem. There are arc marks. B The terminals are not connected securely and there is a contact problem. There are no arc marks. C The terminals are connected securely and there are no contact problems. There are arc marks. B - Connect the No. 6 floor wire (rear motor cable) to the inverter with converter assembly.
- Install the inverter terminal cover.
Result: 2
B
REPLACE MALFUNCTIONING PARTS
Result: 3
C
CONNECT SECURELY
Result: 1
A
See step 13
- Check that the service plug grip is not installed.
- CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)
Refer to PROCEDURE - Step 11
Result
Proceed to OK NG Result: 2
NG
REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2015]
Result: 1
OK
See step 14
- CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)
Refer to PROCEDURE - Step 12
Result
Proceed to OK NG Result: 2
NG
REPLACE HYBRID VEHICLE MOTOR ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2015]
Result: 1
OK
See step 15
- CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (MGR) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the inverter terminal cover from the inverter with converter assembly.
- Disconnect the No. 6 floor wire (rear motor cable) from the inverter with converter assembly.
- Check the rear motor (MGR) for an interphase short using a milliohmmeter.
*1 Shield Ground *a No. 6 floor wire (rear motor cable)
(Inverter with Converter Assembly Side)- Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
HINT:
If the rear motor (MGR) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.
Standard Resistance
Tester Connection Condition Specified Condition R2-3 (R-U) - R2-2 (R-V) Power switch off 163 to 176 mΩ R2-2 (R-V) - R2-1 (R-W) Power switch off 163 to 176 mΩ R2-1 (R-W) - R2-3 (R-U) Power switch off 163 to 176 mΩ HINT:
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).
R20 = Rt / {1 + 0.00393 X (T - 20)}
The calculation is based on the following:
R20: Resistance at 20°C (68°F) (mΩ)
Rt: Measured resistance (mΩ)
T: Temperature when the resistance is measured (°C (°F).)
- Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
- Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.NOTE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance
Tester Connection Condition Specified Condition R2-3 (R-U) - Body ground and shield ground Power switch off 100 MΩ or higher R2-2 (R-V) - Body ground and shield ground Power switch off 100 MΩ or higher R2-1 (R-W) - Body ground and shield ground Power switch off 100 MΩ or higher - Reconnect the No. 6 floor wire (rear motor cable).
- Install the inverter terminal cover.
Result
Proceed to OK NG
Result: 2
NG
See step 33
Result: 1
OK
See step 16
- Check that the service plug grip is not installed.
- CHECK INVERTER WITH CONVERTER ASSEMBLY (NO. 6 FLOOR WIRE CONNECTION CONDITION) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the inverter terminal cover from the inverter with converter assembly.
- Check that the bolt for the No. 6 floor wire is tightened to the specified torque, the No. 6 floor wire is connected securely, and there are no contact problems.
Specified Condition
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
NOTE:Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
- Disconnect the No. 6 floor wire from the inverter with converter assembly.
- Check for arc marks at the bolt and terminals for the No. 6 floor wire.
Result
Result Proceed to The terminals are connected securely and there are no contact problems. There are no arc marks. A The terminals are not connected securely and there is a contact problem. There are arc marks. B The terminals are not connected securely and there is a contact problem. There are no arc marks. C The terminals are connected securely and there are no contact problems. There are arc marks. B - Reconnect the No. 6 floor wire.
- Install the inverter terminal cover.
Result: 2
B
REPLACE MALFUNCTIONING PARTS
Result: 3
C
CONNECT SECURELY
Result: 1
A
See step 17
- Check that the service plug grip is not installed.
- CHECK SERVICE PLUG GRIP (CONNECTION CONDITION) WARNING:
Be sure to wear insulated gloves.
- Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.
OK
Dirt or foreign matter has not entered the connectors, and there is no evidence of contamination.
- Install the service plug grip.
Result
Proceed to OK NG
Result: 2
NG
REPLACE SERVICE PLUG GRIP. Refer to COMPONENTS [02/2014 - ]
Result: 1
OK
See step 18
- Visually check the connection of the service plug grip to the HV battery. Remove the service plug grip and check for contamination.
- INSPECT SERVICE PLUG GRIP
- Remove the service plug grip.
Refer to COMPONENTS [02/2014 - ]
- Measure the resistance according to the value(s) in the table below.
*1 Service Plug Grip Standard Resistance
Tester Connection Condition Specified Condition Service plug grip terminals Always Below 1 Ω - Install the service plug grip.
Result
Proceed to OK NG
Result: 2
NG
REPLACE SERVICE PLUG GRIP. Refer to COMPONENTS [02/2014 - ]
Result: 1
OK
See step 19
- Remove the service plug grip.
- CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (NO. 6 FLOOR WIRE CONNECTION CONDITION) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the No. 8 hybrid vehicle battery shield panel.
Refer to PROCEDURE - Step 30
- Check that the No. 6 floor wire is connected securely, and there are no contact problems.
- Disconnect the No. 6 floor wire from the hybrid battery junction block assembly.
- Check for arc marks on the terminals of the No. 6 floor wire.
Result
Result Proceed to The terminals are connected securely and there are no contact problems. There are no arc marks. A The terminals are not connected securely and there is a contact problem. There are arc marks. B The terminals are not connected securely and there is a contact problem. There are no arc marks. C The terminals are connected securely and there are no contact problems. There are arc marks. B - Reconnect the No. 6 floor wire.
- Install the No. 8 hybrid vehicle battery shield panel.
Result: 2
B
REPLACE MALFUNCTIONING PARTS
Result: 3
C
CONNECT SECURELY
Result: 1
A
See step 20
- Check that the service plug grip is not installed.
- CHECK NO. 6 FLOOR WIRE WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the No. 8 hybrid vehicle battery shield panel.
Refer to PROCEDURE - Step 30
- Disconnect the No. 6 floor wire from the hybrid battery junction block assembly.
- Remove the inverter terminal cover from the inverter with converter assembly.
- Disconnect the No. 6 floor wire from the inverter with converter assembly.
- Measure the resistance according to the value(s) in the table below.
*1 Red Mark *a No. 6 Floor Wire
(Inverter with Converter Assembly Side)*b No. 6 Floor Wire
(Hybrid Battery Junction Block Assembly Side)Standard Resistance
Tester Connection Condition Specified Condition R1-2 (CBI) - R6-1 CBI) Power switch off Below 1 Ω R1-1 (CEI) - R7-1 (CEI) Power switch off Below 1 Ω - Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.NOTE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance
Tester Connection Condition Specified Condition R6-1 - Body ground and shield ground Power switch off 10 MΩ or higher R7-1 - Body ground and shield ground Power switch off 10 MΩ or higher R6-1 - R7-1 Power switch off 10 MΩ or higher - Reconnect the No. 6 floor wire to the hybrid battery junction block assembly.
- Reconnect the No. 6 floor wire to the inverter with converter assembly.
- Install the inverter terminal cover.
- Install the No. 8 hybrid vehicle battery shield panel.
Result
Proceed to OK NG
Result: 2
NG
REPLACE NO. 6 FLOOR WIRE. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 1
OK
See step 21
- Check that the service plug grip is not installed.
- CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRB) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the hybrid battery junction block assembly.
Refer to COMPONENTS [02/2014 - ]
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Hybrid Battery Junction Block Assembly)Standard Resistance
Tester Connection Condition Specified Condition t1-1 (+) - R6-1 (CBI) Auxiliary battery voltage not applied between terminals x3-4 (SMRB) and x3-2 (GND) 10 kΩ or higher t1-1 (+) - R6-1 (CBI) Auxiliary battery voltage applied between terminals x3-4 (SMRB) and x3-2 (GND) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition x3-4 (SMRB) - x3-2 (GND) -40 to 80°C (-40 to 176°F) 18.4 to 36.3 Ω - Install the hybrid battery junction block assembly.
Result
Proceed to OK NG
Result: 2
NG
REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY. Refer to COMPONENTS [02/2014 - ]
Result: 1
OK
See step 22
- Check that the service plug grip is not installed.
- CHECK HV BATTERY JUNCTION BLOCK ASSEMBLY (SMRG) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the hybrid battery junction block assembly.
Refer to COMPONENTS [02/2014 - ]
- Measure the resistance according to the value(s) in the table below.
*a Component without harness connected
(Hybrid Battery Junction Block Assembly)Standard Resistance
Tester Connection Condition Specified Condition u1-1 (-) - R7-1 (CEI) Auxiliary battery voltage not applied between terminals x3-1 (SMRG) and x3-2 (GND) 10 kΩ or higher u1-1 (-) - R7-1 (CEI) Auxiliary battery voltage applied between terminals x3-1 (SMRG) and x3-2 (GND) Below 1 Ω - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition x3-1 (SMRG) - x3-2 (GND) -40 to 80°C (-40 to 176°F) 18.4 to 36.3 Ω - Install the hybrid battery junction block assembly.
Result
Proceed to OK NG
Result: 2
NG
REPLACE HV BATTERY JUNCTION BLOCK ASSEMBLY. Refer to COMPONENTS [02/2014 - ]
Result: 1
OK
See step 23
- Check that the service plug grip is not installed.
- CHECK FUSE (PCU)
Refer to PROCEDURE - Step 13
Result
Proceed to OK NG Result: 2
NG
See step 30
Result: 1
OK
See step 24
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)
Refer to PROCEDURE - Step 14
Result
Proceed to OK NG Result: 2
NG
REPAIR OR REPLACE POWER SOURCE CIRCUIT
Result: 1
OK
See step 25
- CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
Refer to PROCEDURE - Step 15
Result
Proceed to OK NG Result: 2
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
OK
See step 26
- CHECK POWER MANAGEMENT CONTROL ECU
Refer to PROCEDURE - Step 16
Result
Proceed to OK NG Result: 2
NG
REPLACE POWER MANAGEMENT CONTROL ECU. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 1
OK
See step 27
- CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Refer to PROCEDURE - Step 9
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
A
See step 28
- CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Refer to PROCEDURE - Step 10
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
A
See step 29
- CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR)
Refer to PROCEDURE - Step 11
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 1
A
REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - PCU FUSE)
Refer to PROCEDURE - Step 19
Result
Proceed to OK NG Result: 2
NG
See step 32
Result: 1
OK
See step 31
- REPLACE INVERTER WITH CONVERTER ASSEMBLY
Refer to COMPONENTS [02/2014 - 11/2016]
Result
Proceed to NEXT Result: 1
NEXT
REPLACE FUSE (PCU)
- REPAIR OR REPLACE HARNESS OR CONNECTOR
Result
Proceed to NEXT Result: 1
NEXT
REPLACE FUSE (PCU)
- CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (NO. 6 FLOOR WIRE (REAR MOTOR CABLE) CONNECTION CONDITION) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Check that the bolts for the No. 6 floor wire (rear motor cable) are tightened to the specified torque, the No. 6 floor wire (rear motor cable) is connected securely, and there are no contact problems.
Specified Condition
T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)
NOTE:Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).
- Disconnect the No. 6 floor wire (rear motor cable) from the rear traction motor with transaxle assembly
- Check for arc marks at the bolts for the No. 6 floor wire (rear motor cable).
Result
Result Proceed to The terminals are connected securely and there are no contact problems. There are no arc marks. A The terminals are not connected securely and there is a contact problem. There are arc marks. B The terminals are not connected securely and there is a contact problem. There are no arc marks. C The terminals are connected securely and there are no contact problems. There are arc marks. B - Connect the No. 6 floor wire (rear motor cable).
Result: 2
B
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 3
C
CONNECT SECURELY
Result: 1
A
See step 34
- Check that the service plug grip is not installed.
- CHECK NO. 6 FLOOR WIRE (REAR MOTOR CABLE) WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the inverter terminal cover from the inverter with converter assembly.
- Disconnect the No. 6 floor wire (rear motor cable) from the inverter with converter assembly.
- Disconnect the No. 6 floor wire (rear motor cable) from the rear traction motor with transaxle assembly.
- Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.NOTE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance
Tester Connection Condition Specified Condition R2-3 (R-U) - Body ground and shield ground Power switch off 100 MΩ or higher R2-2 (R-V) - Body ground and shield ground Power switch off 100 MΩ or higher R2-1 (R-W) - Body ground and shield ground Power switch off 100 MΩ or higher NOTE:Wrap the terminals of three-phase AC cable with insulating tape to avoid them coming into contact with body ground.
*1 Shield Ground *a No. 6 floor wire (rear motor cable)
(Inverter with Converter Assembly Side)*b No. 6 floor wire (rear motor cable)
(Rear Traction Motor with Transaxle Assembly Side) - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition R2-3 (R-U) - R3-3 (R-U) Power switch off Below 1 Ω R2-2 (R-V) - R3-2 (R-V) Power switch off Below 1 Ω R2-1 (R-W) - R3-1 (R-W) Power switch off Below 1 Ω R2-3 (R-U) - R3-2 (R-V) Power switch off 10 kΩ or higher R2-2 (R-V) - R3-1 (R-W) Power switch off 10 kΩ or higher R2-1 (R-W) - R3-3 (R-U) Power switch off 10 kΩ or higher - Connect the No. 6 floor wire (rear motor cable) to the rear traction motor with transaxle assembly.
- Connect the No. 6 floor wire (rear motor cable) to the inverter with converter assembly.
- Install the inverter terminal cover.
Result
Proceed to OK NG
Result: 2
NG
REPLACE NO. 6 FLOOR WIRE. Refer to COMPONENTS [02/2014 - 11/2016]
Result: 1
OK
See step 35
- Check that the service plug grip is not installed.
- CHECK EXTENSION WIRE ASSEMBLY WARNING:
Be sure to wear insulated gloves.
- Check that the service plug grip is not installed.NOTE:
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair information because this may cause a malfunction.
- Remove the extension wire assembly from the rear traction motor with transaxle assembly.
Refer to COMPONENTS [02/2014 - 11/2016]
- Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.NOTE:
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
Standard Resistance
Tester Connection Condition Specified Condition R-U - Shield shell Power switch off 100 MΩ or higher R-V - Shield shell Power switch off 100 MΩ or higher R-W - Shield shell Power switch off 100 MΩ or higher *1 Extension Wire Assembly *a Shield Shell - Measure the resistance according to the value(s) in the table below.
Standard Resistance
Tester Connection Condition Specified Condition R-U - R-U Power switch off Below 1 Ω R-V - R-V Power switch off Below 1 Ω R-W - R-W Power switch off Below 1 Ω R-U - R-V Power switch off 100 kΩ or higher R-V - R-W Power switch off 100 kΩ or higher R-W - R-U Power switch off 100 kΩ or higher - Install the extension wire.
Result
Proceed to OK NG
Result: 1
OK
REPLACE REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY
Result: 2
NG
REPLACE EXTENSION WIRE ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2016]
- Check that the service plug grip is not installed.
- CHECK CONNECTOR CONNECTION CONDITION (REAR MOTOR RESOLVER CONNECTOR)
Refer to PROCEDURE - Step 12
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
A
See step 37
- INSPECT REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (REAR MOTOR RESOLVER)
Refer to PROCEDURE - Step 13
Result
Proceed to OK NG Result: 1
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 2
NG
REPLACE REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2016]
- CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)
Refer to PROCEDURE - Step 14
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
A
See step 39
- INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR RESOLVER)
Refer to PROCEDURE - Step 15
Result
Proceed to OK NG Result: 1
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 2
NG
REPLACE HYBRID VEHICLE MOTOR ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2015]
- CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)
Refer to PROCEDURE - Step 16
Result
Result Proceed to OK A NG (The connector is not connected securely.) B NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C Result: 2
B
CONNECT SECURELY
Result: 3
C
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 1
A
See step 41
- INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR RESOLVER)
Refer to PROCEDURE - Step 17
Result
Proceed to OK NG Result: 1
OK
REPAIR OR REPLACE HARNESS OR CONNECTOR
Result: 2
NG
REPLACE HYBRID VEHICLE GENERATOR ASSEMBLY. Refer to COMPONENTS [02/2014 - 11/2015]