Home >> Toyota >> 2011 >> Highlander Hybrid Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 42 (Engine Control System (1AR-FE) (Diagnostic Codes (P1604 - U0101) & Circuit Tests)) >> SFI System >> DTC P2004: Intake Manifold Runner Control Stuck Open (Bank 1); DTC P2006: Intake Manifold Runner Control Stuck Closed (Bank 1) >> Monitor Strategy

Monitor Strategy

WARNING: This page is about a different variant/trim than selected.
Related DTCs P2004: Tumble Control Valve Stuck Open
P2006: Tumble Control Valve Stuck Closed
Required Sensors/Components (Main) Tumble control valve
Required Sensors/Components (Related) Intake air temperature sensor, Engine coolant temperature sensor
Frequency of Operation Once per driving cycle
Duration Approximately 10 seconds
MIL Operation 2 driving cycles
Sequence Operation None