DTC P0A7A-517: Generator Inverter Performance; DTC P0A7A-518: Generator Inverter Performance: Procedure
- CHECK DTC OUTPUT (HV)
- Connect the Techstream to the DLC3.
- Turn the power switch on (IG).
- Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
- Check if DTCs are output.
Result
DTC No. Relevant Diagnosis P0A1A (all INF codes) *1 Generator Control Module P0A1B (all INF codes) *1 Drive Motor "A" Control Module P0A1D (Except INF code 390) Hybrid Powertrain Control Module P0A3F-243 Drive Motor "A" Position Sensor Circuit P0A40-500 Drive Motor "A" Position Sensor Circuit Range / Performance P0A41-245 Drive Motor "A" Position Sensor Circuit Low P0A4B-253 Generator Position Sensor Circuit P0A4C-513 Generator Position Sensor Circuit Range / Performance P0A4D-255 Generator Position Sensor Circuit Low P0A60 (all INF codes) *1 Drive Motor "A" Phase V Current P0A63 (all INF codes) *1 Drive Motor "A" Phase W Current P0A72 (all INF codes) *1 Generator Phase V Current P0A75 (all INF codes) *1 Generator Phase W Current P0A78-266, 267, 523, 586 Drive Motor "A" Inverter Performance P0A94-585, 587, 589, 590 DC/DC Converter Performance HINT:
- *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart above.
- Turning the power switch on (IG) with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
- P0A7A-517 or P0A7A-518 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
YES → GO TO DIAGNOSTIC TROUBLE CODE CHART DTC CHART
NO: Go to next step
- CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR). Refer to PROCEDURE - Step 4
NG → CONNECT SECURELY
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER). Refer to PROCEDURE - Step 3
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK MOTOR RESOLVER. Refer to PROCEDURE - Step 4
OK → See step 7
NG: Go to next step
- CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR). Refer to PROCEDURE - Step 5
NG → CONNECT SECURELY
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER). Refer to PROCEDURE - Step 6
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 18
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER). Refer to PROCEDURE - Step 3
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: Go to next step
- CHECK GENERATOR RESOLVER. Refer to PROCEDURE - Step 4
NG → See step 15
OK: Go to next step
- CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION). Refer to PROCEDURE - Step 4
NG → TIGHTEN TO SPECIFIED TORQUE
OK: Go to next step
- CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION). Refer to PROCEDURE - Step 5
NG → TIGHTEN TO SPECIFIED TORQUE
OK: Go to next step
- CHECK HYBRID VEHICLE TRANSAXLE (MG1). Refer to PROCEDURE - Step 6
NG → See step 18
OK: Go to next step
- CHECK HYBRID VEHICLE TRANSAXLE (MG2). Refer to PROCEDURE - Step 7
NG → See step 18
OK: Go to next step
- CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR). Refer to PROCEDURE - Step 5
NG → CONNECT SECURELY
OK: Go to next step
- CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR). Refer to PROCEDURE - Step 5
NG → CONNECT SECURELY
OK → See step 17
- CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR). Refer to PROCEDURE - Step 5
NG → CONNECT SECURELY
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER). Refer to PROCEDURE - Step 6
NG → REPAIR OR REPLACE HARNESS OR CONNECTOR
OK → See step 18
- REPLACE INVERTER WITH CONVERTER ASSEMBLY. Refer to REMOVAL