Inspection Procedure
WARNING: This page is about a different variant/trim than selected.
- INSPECT TRANSMISSION WIRE (SLT)
- Disconnect the transmission wire connector from the transaxle.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 2 (SLT+) - 8 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω - Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short)
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 2 (SLT+) - Body ground Always 10 kΩ or higher 8 (SLT-) - Body ground Always NG: Go to step 3
OK: Go to next step
- CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
- Connect the transmission wire connector to the transaxle.
- Disconnect the ECM connector.
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition B31-76 (SLT+) - B31-75 (SLT-) 20°C (68°F) 5.0 to 5.6 Ω - Measure the resistance according to the value(s) in the table below.
Standard resistance (Check for short)
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition B31-76 (SLT+) - Body ground Always 10 kΩ or higher B31-75 (SLT-) - Body ground Always ↑ NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
OK: REPLACE ECM (See REMOVAL )
- INSPECT SHIFT SOLENOID VALVE SLT
- Remove the shift solenoid valve (SLT).
- Measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE SPECIFICATIONTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
OK: The solenoid makes an operating sound.
NG: REPLACE SHIFT SOLENOID VALVE SLT (See DISASSEMBLY )
OK: REPAIR OR REPLACE TRANSMISSION WIRE (See REMOVAL )