Inspection Procedure
- CHECK CAN COMMUNICATION SYSTEM
- Check for DTCs (See DATA LIST / ACTIVE TEST
).
Result
RESULT CHARTResult Proceed to CAN communication system DTC is not output A CAN communication system DTC is output B
B: Go to CAN COMMUNICATION SYSTEM (See CAN COMMUNICATION SYSTEM )
A: Go to next step.
- Check for DTCs (See DATA LIST / ACTIVE TEST
).
- PERFORM ACTIVE TEST USING TECHSTREAM (TACHOMETER)
- Operate the Techstream according to the display and select Active Test (See DATA LIST / ACTIVE TEST
).
Combination Meter
DIAGNOSTIC NOTE CHARTTester Display Test Part Control Range Diagnostic Note TachoMeter Operation Tachometer 0,1000, 2000, 3000,4000, 5000, 6000, 7000 Perform the test with the vehicle stopped and engine idling. HINT:
Make sure that the vehicle is stopped and the engine is idling.
OK: Needle indication is normal.
NG: REPLACE COMBINATION METER ASSEMBLY (See REMOVAL )
OK: Go to next step.
- Operate the Techstream according to the display and select Active Test (See DATA LIST / ACTIVE TEST
).
- READ VALUE USING TECHSTREAM (TACHOMETER)
- Operate the Techstream according to the display and select Data List (See DATA LIST / ACTIVE TEST
).
Combination Meter
DIAGNOSTIC NOTE CHARTTester Display Measurement Item/Range Normal Condition Diagnostic Note Engine Rpm Engine speed/Min.: 0, Max.: 12750 Idling: 700 to 800 Unit: rpm OK: Engine speed displayed on the Techstream is almost the same as actual engine speed.
NG: Go to step 4
OK: REPLACE COMBINATION METER ASSEMBLY (See REMOVAL )
- Operate the Techstream according to the display and select Data List (See DATA LIST / ACTIVE TEST
).
- READ VALUE USING TECHSTREAM (ENGINE SPEED)
- Operate the Techstream according to the display and select Data List (See DATA LIST / ACTIVE TEST
).
Result
RESULT CHARTResult Proceed to Engine speed displayed on the Techstream is almost same as actual engine speed A Engine speed displayed on the Techstream is not same as actual engine speed B OK: Engine speed displayed on the Techstream is almost the same as actual engine speed.
B: REPLACE ECM (See REMOVAL )
A: REPLACE COMBINATION METER ASSEMBLY (See REMOVAL )
- Operate the Techstream according to the display and select Data List (See DATA LIST / ACTIVE TEST
).