Inspection Procedure
- READ VALUE USING TECHSTREAM (LIGHT CONTROL RHEOSTAT)
- Operate the Techstream according to the display and select Data List (See DATA LIST / ACTIVE TEST
).
Combination Meter
DIAGNOSTIC NOTE CHARTTester Display Measurement Item/Range Normal Condition Diagnostic Note Tail Cancel SW* TAIL cancel switch condition/ON or OFF ON: TAIL cancel switch ON
OFF: TAIL cancel switch OFF- Rheostat value Light control rheostat switch input/Min.: 0, Max.: 100 Light control rheostat switch is fully turned right (0) → fully turned left (100) Unit: % HINT:
*: w/ TAIL Cancel SwitchOK: Light brightness can be changed within specified range by manual operation.
NG: Go to step 2
OK: REPLACE COMBINATION METER ASSEMBLY (See REMOVAL )
- Operate the Techstream according to the display and select Data List (See DATA LIST / ACTIVE TEST
).
- INSPECT LIGHT CONTROL RHEOSTAT
- Inspect the light control rheostat.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Remove the light control rheostat (See REMOVAL ).
- Measure the resistance according to the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Switch Condition Specified Condition 6 (TC) - 1 (E) TAIL cancel switch off → on 10 kΩ or higher → Below 1 Ω 5 (T) - 1 (E) Always 10 kΩ or higher 7 (TR) - 1 (E) Light control rheostat fully turned right → fully turned left 10 kΩ or higher → Below 100 Ω
- Inspect the trip switch.
NG: REPLACE LIGHT CONTROL RHEOSTAT (See REMOVAL )
OK: Go to next step.
- Inspect the light control rheostat.
- CHECK HARNESS AND CONNECTOR (COMBINATION METER - LIGHT CONTROL RHEOSTAT)
- Disconnect the E8 meter connector.
- Disconnect the E9 rheostat connector.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition E8-18 (ILL+) - E9-5 (T) Always Below 1 Ω E8-19 (TR) - E9-7 (TR) E8-23 (E2) - E9-1 (E) E8-20 (TC) - E9-6 (TC)
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
OK: Go to next step.
- REPLACE COMBINATION METER ASSEMBLY
- Replace the combination meter assembly with a new or normally operating one. Perform an operation inspection.
OK: Combination meter assembly operates normally.
NG: GO TO LIGHTING SYSTEM (See LIGHTING SYSTEM )
OK: REPLACE COMBINATION METER ASSEMBLY (See REMOVAL )
- Replace the combination meter assembly with a new or normally operating one. Perform an operation inspection.