Inspection Procedure
- CHECK OPERATION OF STOP LIGHT
- Check that stop light comes on when the brake pedal is depressed and turns off when the brake pedal is released.
OK: Stop lamp switch function is normal.
- NG: REPAIR STOP LIGHT SWITCH CIRCUIT
OK: Go to Next Step.
- Check that stop light comes on when the brake pedal is depressed and turns off when the brake pedal is released.
- CHECK TERMINAL VOLTAGE (STP OF SKID CONTROL ECU - BODY GROUND)
- Disconnect the skid control ECU connector.
- Measure the voltage between terminal STP of the skid control ECU connector and the body ground when the brake pedal is depressed.
Standard:
Brake pedal is depressed: 10 to 14 V
Brake pedal is released: O V
- OK: CHECK AND REPLACE BRAKE ACTUATOR ASSY (SEE REPLACEMENT )
NG: Go to Next Step.
- CHECK HARNESS AND CONNECTOR (STOP LAMP SWITCH - SKID CONTROL ECU) (See ELECTRONIC CIRCUIT INSPECTION PROCEDURE
)
- NG: CHECK AND REPLACE HARNESS AND CONNECTOR
OK: CHECK AND REPLACE BRAKE ACTUATOR ASSY (SEE REPLACEMENT )