Typical Malfunction Thresholds
WARNING: This page is about a different variant/trim than selected.
"Saturated" indicates EVAP pressure change is less than 0.75 mmHg (0.1 kPa) for 30 seconds.
- P2421: Check valve stuck openTYPICAL MALFUNCTION THRESHOLDS (CHECK VALVE STUCK OPEN)
FTP change for 10 seconds when vacuum pump is turned OFF after leak check 1.875 mmHg 0.25 kPa) or more - P2422: Check valve stuck closedTYPICAL MALFUNCTION THRESHOLDS (CHECK VALVE STUCK CLOSED)
Either of the condition A and B is set 0.02 inch leak pressure Less than -33.75 mmHg (-4.5 kPa) or -7.5 mmHg (-1 kPa) or more 0.02 inch leak pressure Not saturated