Monitor Strategy
WARNING: This page is about a different variant/trim than selected.
MONITOR STRATEGY
| Related DTCs | P0171: Fuel System Lean P0172: Fuel System Rich |
| Required sensors/ components (Main) | Fuel system |
| Required sensors / components (Related) | A/F sensor, MAF meter, CKP sensor |
| Frequency of operation | Continuous |
| Duration | 10 sec. |
| MIL operation | 2 driving cycles |
| Sequence of operation | None |