Diagnosis Procedure
- SUSPENSION CONTROL UNIT POWER AND GROUND INSPECTION
Check the suspension control unit power and ground supply. Refer to "SUSPENSION CONTROL UNIT: DIAGNOSIS PROCEDURE ".
Does the suspension control unit power and ground pass inspection?
YES: GO TO 2.
NO: Repair or replace the malfunctioning part.
- CHECK HEIGHT SENSOR SIGNAL INPUT
CONSULT DATA MONITOR
- Turn ignition switch ON.
- Select "HEIGT SEN" of AIR LEVELIZER data monitor item.
- Check the monitor status.
HEIGT SEN: 0.2V - 4.8V
Is the height sensor voltage normal?
YES: GO TO 3.
NO: Check height sensor signal circuit. Refer to "DIAGNOSIS PROCEDURE ".
- CHECK GENERATOR "L" CIRCUIT SIGNAL
CONSULT DATA MONITOR
- Start the engine.
- Select "ACG L" of AIR LEVELIZER data monitor item.
- Check the monitor status.
ACG L
: OFF with charge light OFF
: ON with charge light ON
Is the generator "L" signal operating normally?
YES: GO TO 4.
NO: Check generator L circuit. Refer to "DIAGNOSIS PROCEDURE "(open) and "DIAGNOSIS PROCEDURE "(short).
- SUSPENSION AIR COMPRESSOR POWER AND GROUND INSPECTION
Check the suspension air compressor power and ground supply. Refer to "SUSPENSION AIR COMPRESSOR: DIAGNOSIS PROCEDURE ".
Does the suspension air compressor power and ground pass inspection?
YES: System is operating normally.
NO: Repair or replace the malfunctioning part.