LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2001 >> XL-7 Limited >> Repair and Diagnosis >> External Pages >> Different car >> Section 154 (Engine Cooling) >> Engine Cooling Diagnosis >> Symptom Procedures >> INSPECTION PROCEDURE 3: Radiator Fan and Condenser Fan do not Operate >> Diagnosis >> STEP 8. Check the circuit at fan controller connector A-20 (terminal 1).

STEP 8. Check the circuit at fan controller connector A-20 (terminal 1).

WARNING: This page is about a different car, the 2003 Mitsubishi Outlander. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect fan controller connector A-20, and measure at the harness side connector.
    Fig 1: Disconnecting Fan Controller Connector A-20
    G01864417Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  2. Measure the resistance between terminal number 1 and ground.
    Fig 2: Measuring Resistance Between Terminal Number 1 And Ground
    G01864418Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.

Q: Is the resistance less than 2 ohms? 

  1. YES :  Go to Step 10 .
  2. NO :  Go to Step 9.