LEMON Manuals: Even more car manuals for everyone
Home >> Suzuki >> 2001 >> XL-7 Limited >> Repair and Diagnosis >> External Pages >> Different car >> Section 150 (Manual HVAC System) >> Repair Instructions. >> Operation Procedure for Charging A/C with Refrigerant >> Liquid leak detectors

Liquid leak detectors

WARNING: This page is about a different car, the 2003 Suzuki Vitara, 2003 Suzuki Grand Vitara, 2002 Suzuki Vitara, and 2002 Suzuki Grand Vitara. However, it is still accessible from the selected car via links, so may be relevant.

There are a number of fittings and places throughout the air conditioning system where a liquid leak detector solution may be used to pinpoint refrigerant leaks.

By merely applying the solution to the area in question with a swab, bubbles will form within seconds if there is a leak.

For confined areas, such as sections of the evaporator and condenser, an electronic (gas) leak detector (1) is more practical for determining leaks.

WARNING:
  • To prevent explosions or fires, make sure that there are no flammables in the vicinity.
  • When exposed to fire, the refrigerant turns into a poisonous gas (phosgene). Do not inhale this gas.
Fig 1: Identifying Electronic (Gas) Leak Detector
G01380493Courtesy of SUZUKI OF AMERICA CORP.