Low-Pressure Side Is Low
- CHECK REFRIGERANT LEAKS
.
Check the refrigerant for leaks. Ref. to AIR CONDITIONER>REFRIGERANT LEAK CHECK>INSPECTION .
NOTE: When high-pressure side is less than 0.69 MPa: Go to step 2.Are there refrigerant leaks?
Yes: Repair the refrigerant leaking points.
No: Go to 2.
- FILL PROPER AMOUNT OF REFRIGERANT
.
Drain all refrigerant, and refill proper amount of refrigerant.
- Recovery: Ref. to AIR CONDITIONER>REFRIGERANT RECOVERY PROCEDURE>PROCEDURE .
- Fill: Ref. to AIR CONDITIONER>REFRIGERANT CHARGING PROCEDURE>PROCEDURE .
Is refrigerant pressure within the standard value?
Yes: Refrigerant pressure is normal.
No: Go to 3.
- REPLACE EXPANSION VALVE
.
Replace the expansion valve. Ref. to AIR CONDITIONER>EXPANSION VALVE .
Is refrigerant pressure within the standard value?
Yes: Refrigerant pressure is normal.
No: Inspect the compressor. Ref. to AIR CONDITIONER (DIAGNOSTICS)>DIAGNOSTICS WITH PHENOMENON>INSPECTION>COLD AIR DOES NOT COME OUT EVEN WHEN THE A/C BUTTON IS PRESSED; THE GLASS CANNOT BE DEFOGGED. (COMPRESSOR DOES NOT OPERATE.)