Brake Warning Light (EBD Warning Light)/Electronic Parking Brake Warning Light Does Not Go Off
Detecting condition:
- Defective combination meter
- Brake warning light circuit is shorted.
- Defective sensor/connector
- Defective CAN communication
Trouble symptom:
Electronic parking brake warning light/brake system warning light does not go off when the engine is started.
Wiring diagram:
Parking brake/brake fluid level warning light system Ref. to WIRING SYSTEM>PARKING BRAKE/BRAKE FLUID LEVEL WARNING LIGHT SYSTEM>WIRING DIAGRAM
- CHECK INSTALLATION OF VDC CONTROL MODULE & H/U CONNECTOR
.
- Turn the ignition switch to OFF.
- Check that the VDC Control Module & H/U connector is inserted until it is locked by clamp.
Is the connector firmly inserted?
Yes : Go to 2.
No : Insert the VDC Control Module & H/U connector until it is locked by clamp.
- READ DTC
.
Read the DTC of [Brake Control] using the Subaru Select Monitor. Ref. to BRAKE CONTROL (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC)
Is DTC displayed?
Yes : Perform the diagnosis according to the DTC. Ref. to BRAKE CONTROL (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC)>LIST
No : Go to 3.
- CHECK LAN SYSTEM
.
Check the LAN system. Ref. to LAN SYSTEM (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE
Is the check result OK?
Yes : Go to 4.
No : Perform the diagnosis for LAN system.
- CHECK VDC CONTROL MODULE
.
Using the Subaru Select Monitor, read data of [Parking System Warning Light] in the [Data Monitor] of [Brake Control]. Ref. to BRAKE CONTROL (DIAGNOSTICS)>DATA MONITOR
Is [Parking System Warning Light] set to [ON]?
Yes : Replace the VDC Control Module & H/U. Ref. to VEHICLE DYNAMICS CONTROL (VDC)>VDC CONTROL MODULE AND HYDRAULIC CONTROL UNIT (VDC CONTROL MODULE & H/U)
No : Go to 5.
- CHECK BRAKE FLUID AMOUNT
.
Check the amount of brake fluid in the reservoir tank of master cylinder.
Does the level of the brake fluid amount fall between the lines of "MAX" and "MIN"?
Yes : Go to 6.
No : Replenish brake fluid to the specified value.
- CHECK BRAKE FLUID LEVEL SWITCH
.
- Turn the ignition switch to OFF.
- Disconnect the level switch connector (B99) from master cylinder.
- Measure the resistance of master cylinder terminals.
Terminals
No. 1 - No. 2:
Is the resistance 1 MΩ or more?
Yes : Go to 7.
No : Replace the master cylinder. Ref. to BRAKE>MASTER CYLINDER
- CHECK GROUND SHORT OF HARNESS
.
- Disconnect the connector from VDC Control Module.
- Measure the resistance between VDC Control Module connector and chassis ground.
Connector & terminal
(B66) No. 27 - Chassis ground:
Is the resistance 1 MΩ or more?
Yes : Go to 8.
No : Repair the harness between VDC Control Module and brake fluid level switch.
- CHECK COMBINATION METER
.
Check the combination meter. Ref. to COMBINATION METER (DIAGNOSTICS)>BASIC DIAGNOSTIC PROCEDURE
Is the check result OK?
Yes : Replace the VDC Control Module & H/U. Ref. to VEHICLE DYNAMICS CONTROL (VDC)>VDC CONTROL MODULE AND HYDRAULIC CONTROL UNIT (VDC CONTROL MODULE & H/U)
No : Replace the combination meter. Ref. to INSTRUMENTATION/DRIVER INFO>COMBINATION METER>REMOVAL