< Mode E (reference pressure measurement for canister side judgment)>
WARNING: This page is about a different variant/trim than selected.
Judgment 1
Judge the reference pressure stability.
Judge as NG when the following conditions are established.
Judgment 2
Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions. Judge the vacuum pump performance stability.
Judge as NG when the following conditions are established.
Judgment 3
Judge the presence of evaporative emission system leak.
Judge as NG when the following conditions are established.
JUDGMENT VALUE SPECIFICATIONS
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| Judgment 1 |Pressure sensor maximum output value - Pressure sensor minimum output value| |
More than 314Pa (2.355 mmHg, 0.1 inHg) | P2404 |
| Or, Judgment 2 Reference pressure for judgment |
Less than value of Map3 Or, More than value of Map4 |
P2404 |
| Or, Judgment 3 |Reference pressure for setting the target negative pressure - Reference pressure for judgment| |
More than 0.9 kPa (7.058 mmHg, 0.3 inHg) | P2404 |
BAROMETRIC PRESSURE SPECIFICATIONS - MAP 3
| Barometric pressure (kPa (mmHg, inHg)) | 70 (525, 20.7 inHg) | 80 (600, 23.6 inHg) | 90 (675, 26.6 inHg) | 100 (750, 29.5 inHg) |
|---|---|---|---|---|
| Reference pressure for judgment (kPa (mmHg, inHg)) | -4.5 (-34.020, -1.3 inHg) | -4.6 (-34.815, -1.4 inHg) | -4.7 (-35.618, -1.4 inHg) | -4.9 (-36.420, -1.4 inHg) |
BAROMETRIC PRESSURE SPECIFICATIONS - MAP 4
| Barometric pressure (kPa (mmHg, inHg)) | 70 (525, 20.7 inHg) | 80 (600, 23.6 inHg) | 90 (675, 26.6 inHg) | 100 (750, 29.5 inHg) |
|---|---|---|---|---|
| Reference pressure for judgment (kPa (mmHg, inHg)) | -0.8 (-6.180, -0.2 inHg) | -0.9 (-6.983, -0.3 inHg) | -1 (-7.785, -0.3 inHg) | -1.1 (-8.580, -0.3 inHg) |
Judgment 4
Measure the pressure (leak pressure) when the evaporative emission system becomes the negative pressure by the vacuum pump.
Store the pressure as a leak pressure while the following conditions are met.
JUDGMENT VALUE SPECIFICATIONS
| Malfunction Criteria | Threshold Value | DTC |
|---|---|---|
| < Large leak (0.04 inch)> | P04ED | |
| Leak pressure | Value of Map5 or more |
|
| < Very small leak (0.02 inch)> | P04EF | |
| Leak pressure | More than 0.018 inch reference pressure (Pa) and Less than value of Map5 |
REFERENCE PRESSURE FOR JUDGMENT - MAP5
| Reference pressure for judgment (Pa) | -4856 | -4000 | -2750 | -1500 | -824 |
|---|---|---|---|---|---|
| Threshold Value (Pa) | -1785 | -1463 | -991 | -520 | -265 |