LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2021 >> Crosstrek Sport >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 32 (Engine Control System (HEV) (Diagnostics) (2 Of 4)) >> Diagnostic Procedure With Diagnostic Trouble Code (DTC) >> DTC P04EC: EVAP System Large Leak Detected - Fuel Tank Side >> General Description >> Diagnostic Method >> < Mode E (reference pressure measurement for canister side judgment)>

< Mode E (reference pressure measurement for canister side judgment)>

WARNING: This page is about a different variant/trim than selected.

Judgment 1

Judge the reference pressure stability.

Judge as NG when the following conditions are established.

Judgment 2

Judge whether the reference pressure is within the normal range, and detect the vacuum pump and orifice malfunctions. Judge the vacuum pump performance stability.

Judge as NG when the following conditions are established.

Judgment 3

Judge the presence of evaporative emission system leak.

Judge as NG when the following conditions are established.

JUDGMENT VALUE SPECIFICATIONS

Malfunction Criteria Threshold Value DTC
Judgment 1
|Pressure sensor maximum output value - Pressure sensor minimum output
value|
More than 314Pa (2.355 mmHg, 0.1 inHg) P2404
Or,
Judgment 2
Reference pressure for judgment
Less than value of Map3
Or,
More than value of Map4
P2404
Or,
Judgment 3
|Reference pressure for setting the target negative pressure - Reference pressure for judgment|
More than 0.9 kPa (7.058 mmHg, 0.3 inHg) P2404
BAROMETRIC PRESSURE SPECIFICATIONS - MAP 3

Barometric pressure (kPa (mmHg, inHg)) 70 (525, 20.7 inHg) 80 (600, 23.6 inHg) 90 (675, 26.6 inHg) 100 (750, 29.5 inHg)
Reference pressure for judgment (kPa (mmHg, inHg)) -4.5 (-34.020, -1.3 inHg) -4.6 (-34.815, -1.4 inHg) -4.7 (-35.618, -1.4 inHg) -4.9 (-36.420, -1.4 inHg)
BAROMETRIC PRESSURE SPECIFICATIONS - MAP 4

Barometric pressure (kPa (mmHg, inHg)) 70 (525, 20.7 inHg) 80 (600, 23.6 inHg) 90 (675, 26.6 inHg) 100 (750, 29.5 inHg)
Reference pressure for judgment (kPa (mmHg, inHg)) -0.8 (-6.180, -0.2 inHg) -0.9 (-6.983, -0.3 inHg) -1 (-7.785, -0.3 inHg) -1.1 (-8.580, -0.3 inHg)

Judgment 4

Measure the pressure (leak pressure) when the evaporative emission system becomes the negative pressure by the vacuum pump.

Store the pressure as a leak pressure while the following conditions are met.

JUDGMENT VALUE SPECIFICATIONS

Malfunction Criteria Threshold Value DTC
< Large leak (0.04 inch)>   P04ED
Leak pressure Value of Map5 or
more
 
< Very small leak (0.02 inch)>   P04EF
Leak pressure More than 0.018 inch reference pressure (Pa) and
Less than value of Map5
 
REFERENCE PRESSURE FOR JUDGMENT - MAP5

Reference pressure for judgment (Pa) -4856 -4000 -2750 -1500 -824
Threshold Value (Pa) -1785 -1463 -991 -520 -265