Air Conditioner Does Not Stop Even When The On/Off Switch Turned To Off

WARNING: This page is about a different variant/trim than selected.

Trouble symptom: 

Even when the ON/OFF switch is turned to OFF, the blower fan does not turn off and the compressor does not turn off.

Trouble causes: 

CAUTION: Before performing diagnosis, refer to "CAUTION" in "General Description". Ref. to AIR CONDITIONER (DIAGNOSTICS) (EXCEPT FOR HEV)> GENERAL DESCRIPTION> CAUTION .
  1. CHECK A/C CONTROL PANEL  .
    1. Start the engine.
    2. Turn the ON/OFF switch of the A/C control panel to OFF.
    3. Using the Subaru Select Monitor, check the following items in the [Data Monitor] of [Air Conditioner]. Ref. to AIR CONDITIONER (DIAGNOSTICS) (EXCEPT FOR HEV)> DATA MONITOR .
      • Blower Fan Level
      • Variable Flow Change Solenoid Duty (variable A/C model)

      Does [Blower Fan Level] indicate 0, and [Variable Flow Change Solenoid Duty] indicate 0%?

      Yes:  Go to  2.

      No:  Replace the A/C control panel. Ref. to AIR CONDITIONER (EXCEPT FOR HEV)> CONTROL PANEL .

  2. CHECK BLOWER MOTOR  .

    With the ON/OFF switch turned to OFF, check the blower motor operation.

    Is the blower motor stopped?

    Yes:  Go to  3.

    No:  Ref. to AIR CONDITIONER (DIAGNOSTICS) (EXCEPT FOR HEV)>DIAGNOSTICS WITH PHENOMENON>INSPECTION>AIR GOES OUT OF CONTROL (BLOWER MOTOR ROTATES AT HIGH SPEED) .

  3. CHECK COMPRESSOR  .

    With the ON/OFF switch turned to OFF, check the compressor operation.

    Is the compressor stopped?

    Yes:  The circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.

    NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.

    No:  Ref. to AIR CONDITIONER (DIAGNOSTICS) (EXCEPT FOR HEV)>DIAGNOSTICS WITH PHENOMENON>INSPECTION>COLD AIR DOES NOT COME OUT EVEN WHEN THE A/C SWITCH IS PRESSED. GLASS CANNOT BE DEFOGGED (COMPRESSOR DOES NOT OPERATE (VARIABLE)) .