Inspection When Only Main Fan Does Not Stop

WARNING: This page is about a different variant/trim than selected.
  1. CHECK MAIN FAN RELAY 1  .
    1. Disconnect the ground terminal from battery sensor. Ref. to REPAIR CONTENTS>REPAIR CONTENTS>NOTE>BATTERY .
    2. Remove the main fan relay 1. Ref. to COOLING (H4DO (EXCEPT FOR HEV))>RADIATOR FAN RELAY>LOCATION .
    3. Perform unit check for the main fan relay 1. Ref. to COOLING (H4DO (EXCEPT FOR HEV))>RADIATOR FAN RELAY>INSPECTION .

      Is the main fan relay 1 OK?

      Yes: 

      Go to  2.

      No: 

      1. Replace the main fan relay 1.
      2. Restore the vehicle to its original state.
  2. INSULATION CHECK OF HARNESS BETWEEN MAIN FAN MOTOR AND SUB FAN MOTOR  .
    1. Connect the ground terminal to battery sensor. Ref. to REPAIR CONTENTS>REPAIR CONTENTS>NOTE>BATTERY .
      NOTE: Main fan relay 1 is removed.
    2. Turn to IG ON.
    3. Check the radiator fan operation.

      Does the main fan motor rotate?

      Yes: 

      1. Repair the harness between the main fan motor and the sub fan motor.
      2. Restore the vehicle to its original state.

      No: 

      1. Replace the ECM. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DO (EXCEPT FOR HEV))>ENGINE CONTROL MODULE (ECM) .
      2. Restore the vehicle to its original state.