LH Side
WARNING: This page is about a different variant/trim than selected.
CAUTION:
Before handling the airbag system components, refer to "CAUTION" of "General Description" in "AIRBAG SYSTEM", Ref. to AIRBAG SYSTEM>GENERAL DESCRIPTION>CAUTION
.
- Disconnect the ground terminal from the battery sensor, and wait for at least 60 seconds before starting work. Ref. to REPAIR CONTENTS>REPAIR CONTENTS>NOTE>BATTERY .
- Remove the cover assembly - instrument panel LWR driver. Ref. to EXTERIOR/INTERIOR TRIM>INSTRUMENT PANEL LOWER COVER>REMOVAL .
- Remove the knee airbag module. Ref. to AIRBAG SYSTEM>KNEE AIRBAG MODULE>REMOVAL .
- Remove the duct - foot driver.
- Remove the screws securing the spacer - foot and release the claws, then detach the duct - foot driver together with the spacer - foot.CAUTION: If the duct - foot is detached from the spacer - foot, replace the duct - foot with a new part. If the duct - foot is reused, the holding force of the claws and clips is reduced and the part may come off.
- Remove the screws securing the spacer - foot and release the claws, then detach the duct - foot driver together with the spacer - foot.