DTC P0E51-28: Dc/Dc Converter Current Sensor Signal Bias Level Out Of Range/Zero Adjustment Failure: Notes
1. -
Detecting condition:
Reactor current sensor offset malfunction
When the reactor current sensor output deviates from the specified range in the area where current does not originally flow
(1 trip detection logic)
Trouble symptom:
Reduced output power
- CHECK DTC
.
Read the following DTCs using Subaru Select Monitor. Ref. to P-HEV HYBRID POWERTRAIN CONTROL (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) . Ref. to P-HEV DRIVE MOTOR (DIAGNOSTICS)>DIAGNOSTIC TROUBLE CODE (DTC) .
- P-HEV Hybrid Powertrain Control
- P-HEV Drive Motor
NOTE:Malfunction contents System Related DTC Insulation malfunction P-HEV Hybrid Powertrain Control P1C7C49 HYBRID/EV BATTERY VOLTAGE SYSTEM ISOLATION (A/C AREA) INTERNAL ELECTRONIC FAILURE P1C7D49 HYBRID/EV BATTERY VOLTAGE SYSTEM ISOLATION (HYBRID/EV BATTERY AREA) INTERNAL ELECTRONIC FAILURE P1C7E49 HYBRID/EV BATTERY VOLTAGE SYSTEM ISOLATION (TRANSAXLE AREA) INTERNAL ELECTRONIC FAILURE P1C7F49 HYBRID/EV BATTERY VOLTAGE SYSTEM ISOLATION (DIRECT CURRENT AREA) INTERNAL ELECTRONIC FAILURE Microcomputer malfunction P-HEV Drive Motor P0A1A47 GENERATOR CONTROL MODULE WATCHDOG/SAFETY MC FAILURE P0A1A49 GENERATOR CONTROL MODULE INTERNAL ELECTRONIC FAILURE P0A1B1F GENERATOR CONTROL MODULE CIRCUIT INTERMITTENT P1C2A1C GENERATOR A/D CONVERTER CIRCUIT CIRCUIT VOLTAGE OUT OF RANGE P1C2A49 GENERATOR A/D CONVERTER CIRCUIT INTERNAL ELECTRONIC FAILURE P1C2B1C DRIVE MOTOR "A" CONTROL MODULE A/D CONVERTER CIRCUIT VOLTAGE OUT OF RANGE P1C2B49 DRIVE MOTOR "A" CONTROL MODULE A/D CONVERTER CIRCUIT INTERNAL ELECTRONIC FAILURE P313383 COMMUNICATION ERROR FROM GENERATOR TO DRIVE MOTOR "A" VALUE OF SIGNAL PROTECTION CALCULATION INCORRECT P313386 COMMUNICATION ERROR FROM GENERATOR TO DRIVE MOTOR "A" SIGNAL INVALID P313387 COMMUNICATION ERROR FROM GENERATOR TO DRIVE MOTOR "A" MISSING MESSAGE P313483 COMMUNICATION ERROR FROM DRIVE MOTOR "A" TO GENERATOR VALUE OF SIGNAL PROTECTION CALCULATION INCORRECT P313486 COMMUNICATION ERROR FROM DRIVE MOTOR "A" TO GENERATOR SIGNAL INVALID P313487 COMMUNICATION ERROR FROM DRIVE MOTOR "A" TO GENERATOR MISSING MESSAGE P-HEV Hybrid Powertrain Control P0A1B49 DRIVE MOTOR "A" CONTROL MODULE INTERNAL ELECTRONIC FAILURE Power supply system malfunction P-HEV Drive Motor P06B01C GENERATOR CONTROL MODULE POSITION SENSOR REF POWER SOURCE CIRCUIT VOLTAGE OUT OF RANGE P06D61C GENERATOR CONTROL MODULE OFFSET POWER CIRCUIT VOLTAGE OUT OF RANGE Communication system malfunction P-HEV Drive Motor P312487 LOST COMMUNICATION BETWEEN DRIVE MOTOR "A" AND HV ECU MISSING MESSAGE P-HEV Hybrid Powertrain Control P312387 LOST COMMUNICATION WITH DRIVE MOTOR CONTROL MODULE "A" FROM HYBRID/EV CONTROL MODULE MISSING MESSAGE When "Only DTC P0E5128 is displayed" or "DTC other than above is displayed at the same time", go to A.
When DTCs related to [P-HEV Hybrid Powertrain Control] mentioned above are simultaneously displayed, go to B.
When DTCs related to [P-HEV Drive Motor] mentioned above are simultaneously displayed, go to C.
Yes:
- Go to 2.
- Perform the diagnosis for the simultaneously displayed DTCs.NOTE: If more than one DTC is simultaneously displayed, perform the diagnosis in the order described in the above.
- Perform the diagnosis for the simultaneously displayed DTCs.
NOTE: If more than one DTC is simultaneously displayed, perform the diagnosis in the order described in the above.No: -
- CHECK THE CONNECTING CONDITION OF CONNECTOR (Inverter with converter assembly LOW PRESSURE CONNECTOR)
.CAUTION: Make sure to wear insulated gloves and protective goggles during the work.
- Check that the Service plug is disconnected. Ref. to HYBRID ELECTRIC VEHICLE>SERVICE PLUG .
- Check the connecting condition of low pressure connectors (HV23) and (HV24) in Inverter with converter assembly and check the relevant terminals for contact pressure, deformation and intrusion of water or foreign matter. Ref. to HYBRID ELECTRIC VEHICLE>INVERTER AND CONVERTER ASSEMBLY .
NOTE: When connecting the connector, insert to the end with the lock lever raised, then fold the lock lever completely until a click is heard. After connected, make sure that the lock claw does not loosen and pull the connector to see that it does not come off.Is there looseness at the connector connection, or any poor contact, deformation or intrusion of water or foreign matters at the relevant terminals?
Yes: Connect the connector securely. Or repair the poor contact of connector.
No: Replace Inverter with converter assembly. Ref. to HYBRID ELECTRIC VEHICLE>INVERTER AND CONVERTER ASSEMBLY .