LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2020 >> BRZ tS >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 2 (Automatic Transaxle (Diagnostics)) >> Automatic Transmission System >> DTC B1016: Shift Lock Circuit Failure >> Inspection steps

Inspection steps

WARNING: This page is about a different variant/trim than selected.
  1. Check of shift lock solenoid unit
    1. Check the shift lock solenoid unit. (Refer to UNIT INSPECTION )

      NG: Replacement of shift lock solenoid (refer to REMOVAL )

      OK: Go to next step

  2. Check wiring harness and connector (main body ECM (network gateway computer) - shift lock solenoid)
    NOTE: For inspection procedures and precautions, refer to INSPECTION PROCEDURES FOR ELECTRICAL CIRCUITS AND HOW TO PERFORM .
    1. Disconnect the connector D5 of the main body ECM (network gateway computer).
    2. Disconnect the connector D28 of shift lock solenoid.
    3. Measure the resistance between the terminals.