PCV Pipe: Installation
WARNING: This page is about a different variant/trim than selected.
- Connect the quick connector of the PCV pipe assembly to the PCV connector.CAUTION:
- Check that there is no damage or dust on the quick connector. If necessary, clean the seal surface of the pipe.
- Make sure that the quick connector is securely connected.
- Install the A/C compressor. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>COMPRESSOR>INSTALLATION .
- Attach the clips which secure the PCV pipe assembly to the intake manifold.
- Install the PCV pipe assembly to the clip.
- Install the intake duct No. 2. Refer to INTAKE (INDUCTION) (EXCEPT FOR STI)>INTAKE DUCT>INSTALLATION>INTAKE DUCT NO. 2 .
- Connect the ground terminal to battery sensor. Refer to NOTE>NOTE>BATTERY .
- Charge the A/C system with refrigerant. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>REFRIGERANT CHARGING PROCEDURE>PROCEDURE .
- Install the collector cover. Refer to INTAKE (INDUCTION) (EXCEPT FOR STI)>COLLECTOR COVER>INSTALLATION .