PCV Hose ASSY No. 1
WARNING: This page is about a different variant/trim than selected.
- Disconnect the ground terminal from battery sensor. Refer to NOTE>NOTE>BATTERY .
- Remove the radiator. Refer to COOLING (EXCEPT FOR STI)>RADIATOR>REMOVAL .
- Remove the condenser. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>CONDENSER>REMOVAL .
- Unlock the blow-by diagnosis connector, and disconnect the PCV hose assembly No. 2 from the PCV hose assembly No. 1.
- Remove the blow-by diagnosis connector harness from the PCV hose assembly No. 1.
- Break the clamp, and remove the PCV hose assembly No. 1 from the chain cover.
- Install the PCV hose assembly No. 1 to the chain cover, and install the clamp using the Clamp pincer (14100134).NOTE: Use a new clamp.
- Install the blow-by diagnosis connector harness to the PCV hose assembly No. 1, and connect the PCV hose assembly No. 2 to the PCV hose assembly No. 1.NOTE:
- There are multiple blow-by diagnosis connectors. Be careful not to connect incorrectly.
- Make sure that the blow-by diagnosis connector is connected securely.
- Install the condenser. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>CONDENSER>INSTALLATION .
- Install the radiator. Refer to COOLING (EXCEPT FOR STI)>RADIATOR>INSTALLATION .
- Connect the ground terminal to battery sensor. Refer to NOTE>NOTE>BATTERY .
- Charge the A/C system with refrigerant. Refer to HVAC SYSTEM (HEATER, VENTILATOR AND A/C)>REFRIGERANT CHARGING PROCEDURE>PROCEDURE .
- Fill engine coolant. Refer to COOLING (EXCEPT FOR STI)>ENGINE COOLANT>REPLACEMENT>FILLING OF ENGINE COOLANT .