Thermostat (FA20/For Engine Coolant): Installation
- Thermostat installation
- Install a new gasket to the thermostat.
- Install the thermostat to the thermostat cover.
- Thermostat cover installation
- Install the thermostat cover with the two bolts.
Standard value: T=6.4N.m {65kgf.cm} {4.7ft.lbf}
- Install the thermostat cover with the two bolts.
- Radiator outlet hose connection
- Align the marks marked when removing the hose, install the radiator outlet hose to the thermostat cover and secure the hose with the hose clamp.
- Installation of exhaust manifold (Refer to INSTALLATION )
- Replenishing of coolant (SUBARU Super Coolant) (Refer to COOLANT (FA20) )
- Leak check of coolant (SUBARU Super Coolant) (Refer to COOLING SYSTEM (FA20) )