LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2019 >> BRZ Limited, Automatic Trans >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> Engine Cooling System >> Cooling Fan Motor (FA20) >> Installation

Cooling Fan Motor (FA20): Installation

  1. Cooling fan motor NO. 2 installation
    1. Remove the three screws and install the cooling fan motor NO. 2.

      Standard value: T=3.9N.m {40kgf.cm} {2.9ft.lbf} 

  2. Cooling fan motor installation
    1. Install the cooling fan motor with the three screws.

      Standard value: T=3.9N.m {40kgf.cm} {2.9ft.lbf} 

    2. Connect the wiring harness to the cooling fan motor.
    3. Engage the clamp of connector on the cooling fan motor NO. 2 side to the fan shroud.
  3. Fan NO. 2 installation
    1. Install the fan NO. 2 with the nut.

      Standard value: T=6.3N.m {64kgf.cm} {4.6 ft.lbf} 

  4. Fan installation
    1. Install the fan with the nut.

      Standard value: T=6.3N.m {64kgf.cm} {4.6 ft.lbf} 

  5. Fan shroud installation
    NOTE:
    • Insert a cardboard, blanket, etc. between the radiator ASSY and fan shroud to protect the radiator ASSY.
    • When installing a new fan shroud, put a new radiator gasket (upper side) and cut the radiator gasket (upper side) at the location where the old gasket was cut when removing it.
      1. Insert the fitting area at the lower part of fan shroud to the fitting area at the lower part of radiator ASSY.
        CAUTION:
        • Be careful not to damage the radiator outlet hose, discharge hose and A/C tube & accessory ASSY.
        • Be careful not to damage the radiator inlet hose, radiator hose NO. 1 and water filler SUB-ASSY.
      2. Engage the two claws and install the fan shroud to the radiator ASSY.
      3. Engage the two clamps.
      4. Connect the connector for cooling fan and connector for cooling fan NO. 2.
  6. Radiator support SUB-ASSY installation (Refer to INSTALLATION , Step 11)
  7. Radiator cover plate installation (Refer to INSTALLATION , Step 14)
  8. Air cleaner duct installation (Refer to INSTALLATION , Step 15)
  9. Hood lock ASSY connection (Refer to INSTALLATION )
  10. Water filler SUB-ASSY installation
    1. Install the radiator cap stay with the four bolts.

      Standard value: T=7.5N.m {77kgf.cm} {5.5ft.lbf} 

  11. Radiator reservoir tank ASSY installation (Refer to INSTALLATION , Step 16)
  12. Installation of the front bumper cover (Refer to INSTALLATION )
  13. Installation of air cleaner case SUB-ASSY (Refer to INSTALLATION , Step 18)