DTC B1441 Air Mix Door Actuator Circuit Stuck (Passenger)
DTC detecting condition:
Air mix door actuator RH is locked.
Trouble symptom:
Temperature of the passenger's side cannot be adjusted for model with left/right independent air conditioner.
Wiring diagram:
Air conditioning system <Ref. to WIRING DIAGRAM , Air Conditioning System.>
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK CONNECTOR.
|
Is DTC B1441 displayed? | Go to step 2 . | Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis again.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|
| 2 CHECK ACTUATOR. Using the Subaru Select Monitor, change the setting of «Air mix door actuator target open (passenger's side)» from the A/C diagnosis and perform the system operation check. <Ref. to SYSTEM OPERATION CHECK MODE .> |
Did the actuator move to the specified target opening angle? | Air mix door actuator circuit is normal. | Go to step 3 . |
3 CHECK HARNESS.
Connector & terminal (i175) No. 3 (+) - No. 1 (-): |
Is the voltage 4.5 - 5.0 V? | Go to step 4 . | Repair or replace the open, short circuit of the harness. |
4 CHECK HARNESS (OPEN CIRCUIT).
Connector & terminal (i175) No. 5 - (i80) No. 16: (i175) No. 3 - (i80) No. 12: (i175) No. 1 - (i181) No. 18: (i175) No. 7 - (i181) No. 16: (i175) No. 6 - (i181) No. 15: |
Is there continuity? | Go to step 5 . | Repair or replace the open circuit of harness. |
| 5 CHECK AIR MIX DOOR ACTUATOR RH. Check the air mix door actuator RH parts. <Ref. to INSPECTION , Air Mix Door Actuator.> |
Is the check result OK? | Replace the A/C Control Module. <Ref. to REMOVAL , Control Unit.> | Replace the air mix door actuator RH. <Ref. to REMOVAL , Air Mix Door Actuator.> |