DTC B1500: Fuel Sender Open/Short-Circuit Detection
DTC detecting condition:
The fuel gauge circuit is open or shorted.
Trouble symptom:
- Defective fuel gauge.
- Fuel level warning light blinks.
Wiring diagram:
NOTE:
For the coupling connector, proceed to "WIRING SYSTEM". Fuel gauge system Ref. to
WIRING DIAGRAM
, Fuel Gauge System.
| Step | Check | Yes | No |
|---|---|---|---|
| 1 CHECK DTC. Using the Subaru Select Monitor, read DTC of combination meter. Ref. to READ DIAGNOSTIC TROUBLE CODE (DTC) . |
Is DTC B1500 displayed? (Current malfunction) | Go to step 2 . | Go to step 7 . |
2 CHECK COMBINATION METER.
|
Is the operation of combination meter OK? | Go to step 3 . | Replace the combination meter. Ref. to COMBINATION METER . |
3 CHECK HARNESS (OPEN CIRCUIT).
|
Is the resistance 10 Ω or less? | Go to step 4 . | Repair the open circuit of harness or replace harness. |
| 4 CHECK HARNESS (GROUND SHORT CIRCUIT). Using the tester, measure the resistance between terminals. Connector & terminal (i10) No. 25 - Chassis ground: (i10) No. 26 - Chassis ground: |
Is the resistance 10 Ω or less? | Repair the short circuit of harness or replace harness. | Go to step 5 . |
| 5 CHECK FUEL SUB LEVEL SENSOR. Check the fuel sub level sensor as a single part. Ref. to FUEL SUB LEVEL SENSOR . Ref. to FUEL SUB LEVEL SENSOR . |
Is the check result OK? | Go to step 6 . | Replace the sensor. Ref. to FUEL SUB LEVEL SENSOR . Ref. to FUEL SUB LEVEL SENSOR . |
| 6 CHECK FUEL LEVEL SENSOR. Check the fuel level sensor as a single part. Ref. to FUEL LEVEL SENSOR . Ref. to FUEL LEVEL SENSOR . |
Is the check result OK? | Go to step 7 . | Replace the sensor. Ref. to FUEL LEVEL SENSOR . Ref. to FUEL LEVEL SENSOR . |
7 CHECK CONNECTOR.
|
Is there poor contact of connector? | Repair or replace the poor contact of connector. | Go to step 8 . |
| 8 CHECK CURRENT DATA. Using the Subaru Select Monitor, display «Fuel level resistance» from «Data monitor». Ref. to READ CURRENT DATA . |
Does the data display 10 - 570 Ω? | Even if DTC is displayed, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis.
NOTE:
In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
|
Replace the combination meter. Ref. to COMBINATION METER . |