DTC P2016 TGV Position Sensor/Switch Circuit Low Bank 1: Notes
WARNING: This page is about a different variant/trim than selected.
DTC detecting condition:
Immediately at fault recognition
Trouble symptom:
- Improper idling
- Engine stalls.
- Poor driving performance
CAUTION:
- After servicing or replacing faulty parts, perform Clear Memory Ref. to ENGINE (DIAGNOSTICS) (H4DO)>Clear Memory Mode . and Inspection Mode Ref. to ENGINE (DIAGNOSTICS) (H4DO)>Inspection Mode .
- Use the check board when measuring the ECM terminal voltage and resistance.
Wiring diagram:
Engine Electrical System Ref. to WIRING SYSTEM>Engine Electrical System>WIRING DIAGRAM .
- CHECK CURRENT DATA
.
- Start the engine.
- Using the Subaru Select Monitor, read the value in [TGV Position Sensor R].
NOTE: For detailed operation procedures, refer to the Data Monitor. Ref. to ENGINE (DIAGNOSTICS) (H4DO)>Subaru Select Monitor>OPERATION>DATA MONITOR .Is the value of [TGV Position Sensor R] less than 0.2 V?
- Yes: Go to 2.
- No: Even if DTC is detected, the circuit has returned to a normal condition at this time. Reproduce the failure, and then perform the diagnosis.NOTE: In this case, temporary poor contact of connector, temporary open or short circuit of harness may be the cause.
- CHECK POWER SUPPLY OF TUMBLE GENERATOR VALVE ACTUATOR RH
.
- Turn the ignition switch to OFF.
- Disconnect the connector from tumble generator valve actuator RH.
- Turn the ignition switch to ON.
- Measure the voltage between tumble generator valve actuator RH connector and engine ground.
Connector & terminal
(E55) No. 3 (+) - Engine ground (-):
Is the voltage 4.5 V or more?
- Yes: Go to 3.
- No: repair the harness and connector.NOTE: In this case, repair the following item:
- Open circuit in harness between ECM connector and tumble generator valve actuator RH connector
- Poor contact of ECM connector
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR
.
- Turn the ignition switch to OFF.
- Disconnect the connector from ECM.
- Measure the resistance of harness between ECM connector and tumble generator valve actuator RH connector.
Connector & terminal
(B135) No. 47 - (E55) No. 1:
Is the resistance less than 1 Ω?
- Yes: Go to 4.
- No: Repair the open circuit in harness between ECM connector and tumble generator valve actuator RH connector.
- CHECK HARNESS BETWEEN ECM AND TUMBLE GENERATOR VALVE ACTUATOR RH CONNECTOR
.
Measure the resistance between the ECM connector and engine ground.
Connector & terminal
(B135) No. 47 - Engine ground:
Is the resistance 1 MΩ or more?
- Yes: Go to 5.
- No: Repair the short circuit to ground in harness between ECM connector and tumble generator valve actuator RH connector.
- CHECK FOR POOR CONTACT
.
Check for poor contact of ECM and tumble generator valve actuator RH connector.
Is there poor contact of ECM or the tumble generator valve actuator RH connector?
- Yes: Repair the poor contact of ECM or tumble generator valve actuator RH connector.
- No: Replace the tumble generator valve actuator RH. Ref. to FUEL INJECTION (FUEL SYSTEMS) (H4DO)>Tumble Generator Valve Actuator .