Diagnostic Method
WARNING: This page is about a different variant/trim than selected.
Judge as a malfunction when the high temperature malfunction diagnosis flag of the generator is ON, and at the same time, the regulator temperature inside the generator is at or more than the predetermined value.
JUDGMENT VALUE SPECIFICATION
| Secondary Parameters | Execution condition |
|---|---|
| Internal malfunction flag of generator (high temperature malfunction warning) | = ON |
| Monitor value of generator internal temperature | ≥ 170 °C |
Time needed for diagnosis: 1000 ms
Malfunction indicator light illumination: Does not illuminate even when malfunction occurs. (Charge warning light illuminates.)