LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2013 >> Legacy Premium, Automatic CVT Trans >> Repair and Diagnosis >> Accessories & Equipment >> Drivers Assistance Systems - ADAS >> SUBARU Eyesight System (Driver Assist) (Diagnostics) >> Camera Adjustment, Inspection >> Procedure >> Adjustment Value Clear

Adjustment Value Clear

Perform when replacing stereo camera. (Do not perform when performing stereo camera re-adjustment and inspection)

  1. On «Camera adjustment, inspection» display, select {Camera individual adjustment mode}.
  2. On «Camera individual adjustment mode» display, select {Clear adjustment value}.
  3. When «Perform camera adjustment/inspection. Press OK when the preparations have been made.» is displayed, if preparation is ready, select {OK}.
  4. When «Clear the adjustment value.» is displayed, select {OK}.
  5. When «Clearing adjustment value...» is displayed, wait until process finishes.
  6. When the adjustment value clear is finished correctly, and «Adjustment value cleared OK!» is displayed, select {OK} to finish.
  7. Turn the ignition switch to OFF and wait for approx. 5 seconds or more.
    CAUTION: If the ignition switch OFF period is short, the adjustment value clear can not be performed correctly.
  8. Next, perform the camera all adjustment mode (replacement/removal). < Refer to CAMERA ALL ADJUSTMENT MODE (REPLACEMENT/REMOVAL) , PROCEDURE, Camera Adjustment, Inspection. >